35
CHAPTER 6 MEMORY MAPS
6
6.
1 Rem
ot
e I
/O
S
ignal List
CHAPTER 6
MEMORY MAPS
The NZ2AW1C1BY occupies 1 to 4 stations starting from the station number specified in the CC-Link system.
For information about the buffer memory address of master modules, refer to the user’s manual of the master module
used.
6.1
Remote I/O Signal List
(1) Remote I/O signal when 1 station is occupied
n: Address assigned to the master station in the station number setting
(2) Remote I/O signal when 2 stations are occupied
n: Address assigned to the master station in the station number setting
(3) Remote I/O signal when 3 stations are occupied
n: Address assigned to the master station in the station number setting
(4) Remote I/O signal when 4 stations are occupied
n: Address assigned to the master station in the station number setting
Signal direction: NZ2AW1C1BY to master module
Signal direction: Master module to NZ2AW1C1BY
Remote input (RX)
Name
Remote output (RY)
Name
RXn0 to RX(n+1)9
Use prohibited
RYn0 to RY(n+1)9
Use prohibited
RX(n+1)A
Error status flag
RY(n+1)A
Error reset request flag
RX(n+1)B
Remote station READY
RY(n+1)B to RY(n+1)F
Use prohibited
RX(n+1)C to RX(n+1)F
Use prohibited
Signal direction: NZ2AW1C1BY to master module
Signal direction: Master module to NZ2AW1C1BY
Remote input (RX)
Name
Remote output (RY)
Name
RXn0 to RX(n+3)9
Use prohibited
RYn0 to RY(n+3)9
Use prohibited
RX(n+3)A
Error status flag
RY(n+3)A
Error reset request flag
RX(n+3)B
Remote station READY
RY(n+3)B to RY(n+3)F
Use prohibited
RX(n+3)C to RX(n+3)F
Use prohibited
Signal direction: NZ2AW1C1BY to master module
Signal direction: Master module to NZ2AW1C1BY
Remote input (RX)
Name
Remote output (RY)
Name
RXn0 to RX(n+5)9
Use prohibited
RYn0 to RY(n+5)9
Use prohibited
RX(n+5)A
Error status flag
RY(n+5)A
Error reset request flag
RX(n+5)B
Remote station READY
RY(n+5)B to RY(n+5)F
Use prohibited
RX(n+5)C to RX(n+5)F
Use prohibited
Signal direction: NZ2AW1C1BY to master module
Signal direction: Master module to NZ2AW1C1BY
Remote input (RX)
Name
Remote output (RY)
Name
RXn0 to RX(n+7)9
Use prohibited
RYn0 to RY(n+7)9
Use prohibited
RX(n+7)A
Error status flag
RY(n+7)A
Error reset request flag
RX(n+7)B
Remote station READY
RY(n+7)B to RY(n+7)F
Use prohibited
RX(n+7)C to RX(n+7)F
Use prohibited
Summary of Contents for CC-Link-AnyWire Bitty Bridge
Page 1: ...CC Link AnyWire Bitty Bridge Module User s Manual NZ2AW1C1BY ...
Page 2: ......
Page 9: ...7 Memo ...
Page 14: ...12 Memo ...
Page 24: ...22 2 4 External Dimensions Unit mm 15 4 3 85 141 5 DIN rail 3 8 2 5 66 69 40 100 51 ...
Page 53: ...51 CHAPTER 10 CC LINK I O RESPONSE TIME 10 Memo ...
Page 73: ......