30
4.2.2
Cable processing
Following are recommended solderless terminals for the transmission cables and power cables.
• V1.25-3 (JST Mfg. Co., Ltd.)
• TG1.25-3, TG1.25-3N (Nichifu Terminal Industries Co.,Ltd.)
• V1.25-3 (Fuji Terminal Industry Co. Ltd.)
• 170780-1 (Tyco Electronics AMP K.K.)
The following terminals can be also used for a power cable with a diameter of 2
.
• V2-MS3 (JST Mfg. Co., Ltd.)
• TG2-3N (Nichifu Terminal Industries Co., Ltd.)
For wiring, use wires that meet the specifications of the transmission cable and power cable in the performance
specifications, and tighten them within the applicable tightening torque range. (
Use UL-listed solderless terminals and, for processing, use a tool recommended by their manufacturer.
Tightening torque: 0.5 to 0.8N
m
• Do not run multiple transmission cables (DP, DN) using a multicore cable. Running multiple transmission cables
(DP, DN) together may cause noise, resulting in a malfunction.
• The voltage should not fall below the lower limit of the allowable voltage range due to the voltage drop caused by
the cable. If the voltage falls below the lower limit, malfunctions may occur.
• Do not connect soldered cables directly to the terminals. Doing so may loosen the screws, resulting in a poor
contact.
• Use a crimping tool to connect a cable to a bar solderless terminal.
• Before inserting a bar solderless terminal, check the shapes of the wire insertion opening and bar solderless
terminal. Then, insert the terminal in the correct orientation. Inserting a bar solderless terminal wider than the wire
insertion opening may damage the terminal block.
DP
DN
DP
DN
DP
DN
DP
DN
Summary of Contents for CC-Link-AnyWire Bitty Bridge
Page 1: ...CC Link AnyWire Bitty Bridge Module User s Manual NZ2AW1C1BY ...
Page 2: ......
Page 9: ...7 Memo ...
Page 14: ...12 Memo ...
Page 24: ...22 2 4 External Dimensions Unit mm 15 4 3 85 141 5 DIN rail 3 8 2 5 66 69 40 100 51 ...
Page 53: ...51 CHAPTER 10 CC LINK I O RESPONSE TIME 10 Memo ...
Page 73: ......