5
PROGRAMS COMPARISONS
5
- 5
*
The XY address specified by the buffer memory read/write instruction "FROM/TO" becomes the XY address in the program.
The following shows the XY address of each module when the FROM/TO instruction is programmed.
Remarks
(1)
I/O signals of the AnyWire DB A20 master module
I/O signals of the master module indicate the state of the module, and are used as command
output. This is different from using as ON/OFF signals of the remote station for MELSEC-I/OLINK.
The "n" in the table is the start I/O number of the master module which is determined according to
the mounted position and modules mounted before the master module.
*1
Use prohibited for the LJ51AW12D2.
*2
When 8 is set for "Switch 1", the settings are as follows.
Xn8: OFF, Xn9: OFF, XnA: OFF, XnB: O
*3
Use prohibited for the QJ51AW12D2.
*4
The QJ51AW12D2 with a serial number where the sixth digit is "6" or later can be used.
When the start I/O number of the master module is "X/Y10"
Xn0 to X(n+1)F
X10 to X2F
Yn0 to X(n+1)F
Y10 to Y2F
Input number
Signal name
Output number
Signal name
Xn0
Module READY
Yn0
Disconnection flag reset command output
Xn1
Short between D and G terminals
Yn1
Automatic address detection command
output
Xn2
Short between D and 24V terminals
Yn2
*4
Transmission waveform output command
Xn3
24V not applied
Yn3 to YnF
Use prohibited
Xn4
D/G line disconnection
Xn5 to Xn7
Use prohibited
Xn8 to XnB
*1
"Switch Setting for I/O and Intelligent
Function Module"
Switch 1 setting value
*2
XnC to XnF
Use prohibited
X(n+1)0 to
X(n+1)3
Use prohibited
Y(n+1)0 to
Y(n+1)F
Use prohibited
X(n+1)4
*3
Automatic address detection flag
X(n+1)5 to
X(n+1)F
Use prohibited
Unused due to
fractional points
Unused
(used area for the existing output module AJ55TB2-8T)
A20SB-04U (input: 4 points)
X1000 to X1003
Buffer memory
address
100
H
101
H
102
H
Buffer memory
address
1100
H
1101
H
1102
H
A20XB-16UD (input: 8 points)
X1018 to X101F
Unused
Unused due to
fractional points
A20XB-16UD (input: 8 points)
X1010 to X1017
A20XB-08UD (input: 8 points)
X1020 to X1027
Unused (used area for the
existing input module
AJ55TB3-40)
A20PB-08U (output: 8 points)
Y1004 to Y101B
A20XB-16UD (output: 8 points)
Y1018 to Y101F
Unused
A20XB-16UD (output: 8 points)
Y1010 to Y1017
Unused
(used area for the existing input module AJ55TB32-8D)
FROM
TO
H0C
H0C
H1100
H100
K4X1000
K4Y1000
K3
K3
Ex.
Summary of Contents for AnyWire DB A20
Page 1: ...Transition from MELSEC I OLINK to AnyWire DB A20 Handbook Feb 2017 Edition ...
Page 2: ......
Page 27: ...4 REPLACING THE MASTER MODULE 4 2 Memo ...
Page 76: ...APPX 3 Memo ...
Page 79: ......