28
4.6 Optical axis adjustment
4.6.1 Precautions for optical axis adjustment
For the optical axis adjustment, pay attention to the following.
(1) Adjust the optical axis of each system to the center of the light
receiving level area as much as possible. (Refer to Section 4.6.2.)
When multiple sets of the AJ65BT-RPI-10A/10B are used in
parallel, turn off the other system(s) before starting the optical axis
adjustment.
(2) When the AJ65BT-RPI-10A/10B is installed to a movable body,
check that the adjusted position in the light receiving level is not
lowered during movement.
(3) When multiple sets of the AJ65BT-RPI-10A/10B are used in
parallel, check that the individual system is not affected by
interference light from the other system. (Refer to Section 4.6.3.)