background image

5

2.9. Emergency operation

When the remote controller cannot be used

When the batteries of the remote controller run out or the remote controller
malfunctions, the emergency operation can be done using the emergency
buttons on the grille.

A

DEFROST/STAND BY lamp

B

Operation lamp

C

Emergency operation switch (heating)

D

Emergency operation switch (cooling)

E

Receiver

Starting operation
• To operate the cooling mode, press the 

 button 

D

.

• To operate the heating mode, press the 

 button 

C

.

Note:
• Details of emergency mode are as shown below.

Details of EMERGENCY MODE are as shown below. However, the tem-
perature control does not work for 30 minutes in test run and the unit is set
to continuous operation. The fan speed is set to High in test run and shifts
to Medium after 30 minutes.

Operation mode

COOL

HEAT

Set temperature

24°C

24°C

Fan speed

med.

med.

Airflow direction

Horizontal 30°

Downward 70°

Stopping operation
• To stop operation, press the 

 button 

D

 or the 

 button 

C

.

A B C D

E

B

A

D

C

3. Care and cleaning

 Caution:

Always turn off the power, first on the remote controller and then
the main switch, before cleaning or servicing the unit.

When installing or removing the filter or the intake grille, do not
stand on an unsteady surface. You may fall and injure yourself. Be
also careful not to let dust fall into your eyes.

Dirty or clogged filters block the airflow and reduce efficiency. Very dirty
filters can damage the air-conditioner itself.

Intake grille removal

1

Pull the catch on the intake grille in the direction indicated by the arrow
and it should open.

2

Unhook the hinges to remove the intake grille from the grille.

Filter removal

1

Open the intake grille.

2

Release the catch on the center edge of the intake grille and pull the
filter forward to remove the filter.

A

 Catch

B

 Grille

C

 Intake grille

D

 Filter

3.1. Cleaning the filters and the indoor unit

Cleaning the filter

• Clean the filter using a vacuum cleaner. If you do not have a vacuum

cleaner, tap the filter against a solid object to knock off dirt and dust.

• If the filter is especially dirty, wash it in lukewarm water. Take care to

rinse off any detergent thoroughly and allow the filter to dry completely
before putting it back into the unit.

 Caution:

• Do not dry the filter in direct sunlight or by using a heat source,

such as an electric heater: this may warp it.

• Do not wash the filter in hot water (above 50°C), as this may warp

them.

• Make sure that the air filter is always installed. Operating the unit

without air filter can cause malfunction.

Cleaning the indoor unit

• Wipe the outside of the unit with a clean, dry, soft cloth.
• Clean off any oil stains or finger marks using a neutral household deter-

gent (such as dishwashing liquid or laundry detergent).

 Caution:

Never use gasoline, benzene, thinner, scouring powder or any type of
non-neutral detergent, as these substances may damage the unit’s
case.

2. Operation

Summary of Contents for A12

Page 1: ...orlezen voordat u de airconditioner gebruikt ISTRUZIONI DI FUNZIONAMENTO Leggere attentamente questi istruzioni di funzionamento prima di avviare l unità per un uso corretto e sicuro della stessa MANUAL DE INSTRUCCIONES Lea este manual de instrucciones hasta el final antes de poner en marcha la unidad de aire acondicionado para garantizar un uso seguro y correcto MANUAL DE OPERAÇÃO Para segurança ...

Page 2: ...water over the unit and do not touch the unit with wet hands An electric shock may result Do not spray combustible gas close to the unit Fire may result Do not place a gas heater or any other open flame appliance where it will be exposed to the air discharged from the unit Incomplete combustion may result Ventilate the room if refrigerant leaks during operation If the refrigerant comes in contact ...

Page 3: ...ed if there is interference of light of fluorescent lights or strong sunlight 2 4 Mode select 1If the unit is off press the ON OFF button to turn it on 2Press the operation mode MODE button and select the operation mode Each time the operation mode MODE button is pressed the moves A SLZ A09 A12 A18AR Automatic cooling heating mode Cooling mode Drying mode Heating mode Information for multi system ...

Page 4: ...displayed on the remote controller as shown below 1 2 3 4 5 1 Horizontal airfrow 30 4 Downword airfrow 70 2 Downword airfrow 45 5 Swing 3 Downword airfrow 55 In either cooling or drying mode if you select 2 or 3 or 4 when the fan speed is Low or Medium the airconditioner will switch automatically to Horizontal airflow 1 mode after one hour In the following situations the display differs from the v...

Page 5: ...s block the airflow and reduce efficiency Very dirty filters can damage the air conditioner itself Intake grille removal 1Pull the catch on the intake grille in the direction indicated by the arrow and it should open 2Unhook the hinges to remove the intake grille from the grille Filter removal 1Open the intake grille 2Release the catch on the center edge of the intake grille and pull the filter fo...

Page 6: ... too low and humidity is too high frost is formed Before you call out a repair man check the following table to see whether there is a simple solution to your problem If none of the above apply turn the main switch off and contact the dealer from whom you bought the air conditioner telling him the model name and the nature of the problem Do not try to fix the unit yourself In any of the following ...

Page 7: ...ity or increase operating sound If abnormal sound is heard during operation consult your dealer Relocation When the air conditioner is to be removed or reinstalled because of rebuilding moving etc special techniques and work are required Warning Repair or relocation should not be done by the customer If this is done incorrectly it may cause a fire electric shock injury by dropping of the unit wate...

Page 8: ...EC Electromagnetic Compatibility Directive 89 336 EEC This product is designed and intended for use in the residential commercial and light industrial environment HEAD OFFICE MITSUBISHI DENKI BLDG 2 2 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN Printed in Thailand BG79U162H01 The product at hand is based on the following EU regulations ...

Reviews: