(N) Operation via communication and its settings
567
5
GROUP
N
Operation command
The signal within parentheses ( ) is the initial status. The description changes depending on the setting of
Pr.180 to Pr.184, Pr.187 (Input
terminal function selection)
(
The inverter run enable signal is in the initial status for the separated converter type.
JOG operation/automatic restart after instantaneous power failure/start self-holding selection/reset cannot be controlled over a network, so in the
initial status bit8 to bit11 are invalid. To use bit8 to bit11, change the signal by
Pr.185, Pr.186, Pr.188, or Pr.189 (Input terminal function
selection)
(
(A reset can be executed by the instruction code HFD.)
In RS-485 communication from the PU connector, only the forward rotation command and reverse rotation command can be used.
Inverter status monitor
The signal within parentheses ( ) is the initial status. The description changes depending on the setting of
Pr.190 to Pr.196 (Output terminal
function selection)
.
No function is assigned in the initial status for the separated converter type.
Item
Instruction
code
Bit
length
Description
Example
Operation
command
HFA
8 bits
b0: AU (Terminal 4 input selection)
b1: Forward rotation command
b2: Reverse rotation command
b3: RL (Low-speed operation command)
b4: RM (Middle-speed operation
command)
b5: RH (High-speed operation
command)
b6: RT (Second function selection)
b7: MRS (Output stop)
Operation
command
(extended)
HF9
16 bits
b0: AU (Terminal 4 input selection)
b1: Forward rotation command
b2: Reverse rotation command
b3: RL (Low-speed operation command)
b4: RM (Middle-speed operation
command)
b5: RH (High-speed operation
command)
b6: RT (Second function selection)
b7: MRS (Output stop)
b8: JOG (Jog operation selection)
b9: CS (Selection of automatic restart
after instantaneous power failure, flying
start)
b10: STP (STOP) (Start self-holding
selection)
b12 to b15: -
Item
Instruction
code
Bit
length
Description
Example
Inverter
status
monitor
H7A
8 bits
b0: RUN (Inverter running)
b1: During forward rotation
b2: During reverse rotation
b3: SU (Up to frequency)
b4: OL (Overload warning)
b5: IPF (Instantaneous power failure/
undervoltage)
b6: FU (Output frequency detection)
b7: ABC1 (Fault)
Inverter
status
monitor
(extended)
H79
16 bits
b0: RUN (Inverter running)
b1: During forward rotation
b2: During reverse rotation
b3: SU (Up to frequency)
b4: OL (Overload warning)
b5: IPF (Instantaneous power failure/
undervoltage)
b6: FU (Output frequency detection)
b7: ABC1 (Fault)
b8: ABC2 (
―
)
b9 to b14: -
b15: Fault occurrence
0
0
0
0
0
0
1
0
b7
b0
[Example 1] H02 Forward rotation
[Example 2] H00 Stop
0
0
0
0
0
0
0
0
b7
b0
0
0
0
0
0
0
1
0
b0
[Example 1] H0002 Forward rotation
0
0
0
0
0
0
0
0
b15
0
0
0
0
0
1
0
0
b0
[Example 2] H0804 Low-speed reverse operation
(When
Pr. 189 RES terminal function selection
is set to "0")
0
0
0
0
1
0
0
0
b15
0
0
0
0
0
0
1
1
b7
b0
1
0
0
0
0
0
0
0
b7
b0
[Example 2] H80
[Example 1] H03
Stop at fault
occurrence
During forward
rotation
0
0
0
0
0
0
1
1
b0
0
0
0
0
0
0
0
0
b15
[Example 1] H0003 During forward rotation
1
0
0
0
0
0
0
0
b0
1
0
0
0
0
0
0
0
b15
[Example 2] H8080 Stop at fault occurrence
Summary of Contents for 800 Series
Page 11: ...MEMO 10 ...
Page 17: ...MEMO 16 ...
Page 95: ...MEMO 94 ...
Page 671: ...MEMO 670 ...
Page 681: ...MEMO 680 ...