Control method
146
Initial value for the FR-A860-01080 or lower.
Initial value for the FR-A860-01440 and higher.
110% for SLD, 120% for LD, 150% for ND, and 200% for HD (Refer to
Pr.570 Multiple rating setting
.)
The
Pr.702 Maximum motor frequency
is used as the maximum motor frequency. When
Pr.702
=“9999 (initial value)", the
Pr.84 Rated motor
frequency
is used as the maximum motor frequency.
NOTE
• If PM parameter initialization is performed in rotations per minute (
Pr.998
=
"8009 or 9009"), the parameters not listed in the table
and the monitored items are also set and displayed in rotations per minute.
13
Starting frequency
0.5 Hz
Pr.84
10%
Pr.84
10%
1 r/min
0.01 Hz
15
Jog frequency
5 Hz
Pr.84
10%
Pr.84
10%
1 r/min
0.01 Hz
18
High speed maximum frequency
120 Hz
―
―
1 r/min
0.01 Hz
20
Acceleration/deceleration reference frequency 60 Hz
Pr.84
Pr.84
1 r/min
0.01 Hz
22
Stall prevention operation level
150%
0.1%
37
Speed display
0
0
1
55
Frequency monitoring reference
60 Hz
Pr.84
Pr.84
1 r/min
0.01 Hz
56
Current monitoring reference
Inverter rated
current
Pr.859
Pr.859
71
Applied motor
0
―
―
1
80
Motor capacity
9999
―
―
0.01 kW
81
Number of motor poles
9999
―
―
1
84
Rated motor frequency
9999
―
―
1 r/min
0.01 Hz
116
Third output frequency detection
60 Hz
Pr.84
Pr.84
1 r/min
0.01 Hz
125
(903)
Terminal 2 frequency setting gain frequency
60 Hz
Pr.84
Pr.84
1 r/min
0.01 Hz
126
(905)
Terminal 4 frequency setting gain frequency
60 Hz
Pr.84
Pr.84
1 r/min
0.01 Hz
144
Speed setting switchover
4
Pr.81
+100
Pr.81
1
240
Soft-PWM operation selection
1
0
1
263
Subtraction starting frequency
60 Hz
Pr.84
Pr.84
1 r/min
0.01 Hz
266
Power failure deceleration time switchover
frequency
60 Hz
Pr.84
Pr.84
1 r/min
0.01 Hz
374
Overspeed detection level
9999
Maximum motor
fr10 Hz
Maximum motor
frequency+10 Hz
1 r/min
0.01 Hz
386
Frequency for maximum input pulse
60 Hz
Pr.84
Pr.84
1 r/min
0.01 Hz
505
Speed setting reference
60 Hz
Pr.84
Pr.84
0.01 Hz
557
Current average value monitor signal output
reference current
Inverter rated
current
Pr.859
Pr.859
820
Speed control P gain 1
60%
30%
1%
821
Speed control integral time 1
0.333 s
0.333 s
0.001 s
824
Torque control P gain 1 (current loop
proportional gain)
100%
100%
1%
825
Torque control integral time 1 (current loop
integral time)
5 ms
20 ms
0.1 ms
870
Speed detection hysteresis
0 Hz
8 r/min
0.5 Hz
1 r/min
0.01 Hz
885
Regeneration avoidance compensation
frequency limit value
6 Hz
Pr.84
10%
Pr.84
10%
1 r/min
0.01 Hz
893
Energy saving monitor reference (motor
capacity)
Inverter rated
capacity
Motor capacity
(Pr.80)
0.01 kW
918
Terminal 1 gain frequency (speed)
60 Hz
Pr.84
Pr.84
1 r/min
0.01 Hz
1121 Per-unit speed control reference frequency
120 Hz
Maximum motor
frequency
Maximum motor
frequency
1 r/min
0.01 Hz
―
: Not changed
Pr.
Name
Setting
Setting
increments
Induction
motor
PM motor
(rotations per
minute)
PM motor
(frequency)
Pr.998
0
(initial value)
8009
9009
8109
9109
8009,
9009
0, 8109,
9109