Mitsubishi Electric 13JZ96 User Manual Download Page 23

21

3.

Hold the connector part of the cable, and insert it to the connector of the QA1S6ADP-S1.

4.

Fix the cable with the fixing screws (tightening torque: 0.20N

m).

When connecting the QA1S6ADP-S1 to the upper level extension base unit with an 
extension cable, connect the IN side connector of the QA1S6ADP-S1 and the OUT 
side connector of the upper level extension base unit. The system will not operate 
properly if the extension cable is connected to the wrong connectors (IN side and IN 
side of both connectors, OUT side and OUT side of both connectors, or OUT side 
connector of the QA1S6ADP-S1 and IN side connector of the upper level extension 
base unit).

Disconnecting procedure

To disconnect the extension cable, loosen and remove the fixing screws, and then disconnect 
the cable holding the connector part.

Connector

Extension base unit

Extension cable

QA1S6ADP-S1

Fixing screw

Flathead screwdriver

Extension base unit

QA1S6ADP-S1

Summary of Contents for 13JZ96

Page 1: ...chasing the Mitsubishi Electric MELSEC AnS series programmable controllers Before using this product please read this manual and relevant manuals carefully to handle the product correctly 2014 MITSUBISHI ELECTRIC CORPORATION MODEL QA1S6ADP S1 U E MODEL CODE 13JZ96 IB NA 0800539ENG B 1612 MEE ...

Page 2: ......

Page 3: ...e of the PRODUCT in Nuclear Power Plants and any other power plants operated by Power companies and or any other cases in which the public could be affected if any problem or fault occurs in the PRODUCT Railway companies or Public service purposes and or any other cases in which establishment of a special quality assurance system is required by the Purchaser or End User Aircraft or Aerospace Medic...

Page 4: ... 4 1 Part Names 14 4 2 Extension Level Setting 15 Setting of the QA1S6ADP S1 15 Setting of the extension base unit 15 5 MOUNTING AND INSTALLATION 16 5 1 Mounting Removing the QA1S6ADP S1 16 Precautions 16 Mounting procedure 16 Removing procedure 18 5 2 Connecting Disconnecting Extension Cables 19 Precautions 19 Extension cable specifications 19 Connecting procedure 20 Disconnecting procedure 21 6 ...

Page 5: ...3 Appendix 1 Marking and Information Disclosure for the Restriction on Use of Hazardous Sub stances in Electrical and Electronic Products Required by the New China RoHS 26 REVISIONS 28 WARRANTY 30 ...

Page 6: ... O modules and special function modules can be mounted A1S6 B A generic term for the A1S65B S1 and A1S68B S1 extension base units type requiring power supply module where AnS series I O modules and special function modules can be mounted QA1S6ADP S1 The abbreviation for the QA1S6ADP S1 Q AnS base unit conversion adapter QA1S6ADP S1 A1S5 B A1S6 B The abbreviation for the AnS series extension base u...

Page 7: ...5 MEMO ...

Page 8: ...s d erreur du module de CPU reportez vous au QCPU User s Manual Hardware Design Maintenance and Inspection le Manuel de l utilisateur QCPU conception du matériel maintenance et inspection 1 2 QA1S6ADP S1 The QA1S6ADP S1 is an adapter to connect an AnS series extension base unit to a Q series base unit The QA1S6ADP S1 is a CE marked product To comply with the EMC Directive the extension base units ...

Page 9: ...ial metal fixture A 1 Special metal fixture B 1 Adapter mounting screw M3 6 3 Special metal fixture mounting screw M5 25 2 Special metal fixture mounting screw M5 28 2 Plain washer M5 3 Fixing screw cover 4 This manual 1 Item Model Remarks Q series extension cable QC05B This cable is required to connect the AnS series extension base unit with the QA1S6ADP S1 mounted to the Q series main base unit ...

Page 10: ...1 20 19 18 17 16 31 30 29 28 27 26 25 24 1 2 3 A1S68B S1 A1S68B S1 Q38B Q68B AnS series extension base unit with the QA1S6ADP S1 QA1S6ADP S1 A1S5 B A1S6 B Q series extension base unit Q5 B Q6 B Main base unit Q3 B CPU module Extension level setting connector Level setting Power supply module Power supply module Power supply module Power supply module Q series extension cable ...

Page 11: ...l to the extension level setting connectors of the QA1S6ADP S1 and the extension base unit When the QA1S6ADP S1 A1S5 B A1S6 B is used the number of extension base units is limited to three including the number of Q series extension base units Software The number of slots of the QA1S6ADP S1 A1S5 B A1S6 B is always displayed as eight in GX Works2 or GX Developer regardless of the actual number of sl...

Page 12: ... A1SY10 A1SY10EU A1SY14EU A1SY18A A1SY18AEU Triac output module A1SY22 A1SY28A Transistor output module A1SY40 A1SY40P A1SY41 A1SY41P A1SY42 A1SY42P A1SY50 A1SY60 A1SY60E A1SY68A A1SY71 A1SY80 A1SY81 A1SY82 Dynamic output module A1S42Y I O combined module A1SH42 A1SH42 S1 A1SX48Y58 A1SX48Y18 High speed counter module A1SD61 A1SD62 A1SD62E A1SD62D A1SD62D S1 1 A D converter module A1S64AD A1S68AD D...

Page 13: ...dule A1SJ71AP23Q A1SJ71AR23Q A1SJ71AT23BQ Paging interface module A1SD21 S1 3 Position detection module A1S62LS PC fault detection module A1SS91 Memory card interface module A1SD59J S2 ID interface module A1SD35ID1 A1SD35ID2 3 MELSECNET I O LINK master module A1SJ51T64 B NET interface module A1SJ71B62 S3 JEMANET OPCN 1 interface module A1SJ71J92 S3 3 S LINK master module A1SJ71SL92N AS i master mo...

Page 14: ... of the environment in which the equipment is used Pollution level 2 is when only non conductive pollution occurs A temporary conductivity caused by condensing must be expected occasionally Item Specifications Operating ambient temperature Température ambiante de fonctionnement 0 to 55 0 à 55 Storage ambient temperature 20 to 75 Operating ambient humidity 10 to 90 RH non condensing Storage ambient...

Page 15: ... of the QA1S6ADP S1 Item Specifications Internal current consumption 5VDC 150mA External dimensions H 130mm W 62mm D 78 5mm Weight 0 28kg Tightening torque range of adapter mounting screw M3 0 36 to 0 48N m Tightening torque range of special metal fixture mounting screw M5 1 59 to 2 16N m ...

Page 16: ...level setting connector A connector for setting the level of the extension base unit 3 Connector for extension base unit A connector to be connected to the extension cable connector of the extension base unit 4 Adapter mounting screw M3 A screw for mounting the adapter on the extension base unit 5 Ground cable guide hole A guide hole for placing the ground cable connected to the FG terminal of the...

Page 17: ...irst use of the product do not set the extension level setting connectors more than 10 times Setting of the QA1S6ADP S1 Set the extension level setting connector of the QA1S6ADP S1 as shown below Setting of the extension base unit Set the extension level setting connector of the extension base unit following the procedure below Extension level 1st level 2nd level 3rd level Setting of the extension...

Page 18: ...s extension cable from the extension base unit 2 Remove the base cover from the extension base unit 3 Disconnect the ground cable from the FG terminal of the A1S5 B when the A1S5 B is used 4 Set the extension level of the extension base unit 5 Set the extension level of the QA1S6ADP S1 Set the same level as the one set to the extension base unit 6 Mount the special metal fixture in accordance with...

Page 19: ...acket A1S PLT D sold separately and ground cable as shown on the left Extension base unit Ground cable Special metal fixture A Special metal fixture B Special metal fixture mounting screw M5 25 Special metal fixture mounting screw M5 28 FG terminal Plain washer M5 Extension base unit Ground cable Special metal fixture A Plain washer M5 Vibration proofing bracket A1S PLT D Special metal fixture mou...

Page 20: ...nit Insert the connector of the QA1S6ADP S1 to the extension cable connector IN side of the extension base unit and fix the adapter with the adapter mounting screws three locations Pull out the ground cable connected to the FG terminal of the A1S5 B through the guide hole when the A1S5 B is used Mount the covers marked 1 to the upper screws and those marked 2 to the lower screws as shown on the le...

Page 21: ...ld the ferrite cores installed at both ends of each cable Hold the connector part of the cable Holding the ferrite core may cause the cable disconnection inside the connector Besides keep the ferrite core in the correct position If the ferrite core position is shifted the characteristic will change Extension cable specifications The following table lists the extension cables that can be connected ...

Page 22: ...A1S6ADP S1 2 Remove the thin walled part of the extension cable connector OUT side of the QA1S6ADP S1 using a tool such as a flathead screwdriver 5 5 75 6 100 Sticker Extension base unit QA1S6ADP S1 Cuts on the thin walled part two locations Flathead screwdriver Extension base unit QA1S6ADP S1 ...

Page 23: ...se unit The system will not operate properly if the extension cable is connected to the wrong connectors IN side and IN side of both connectors OUT side and OUT side of both connectors or OUT side connector of the QA1S6ADP S1 and IN side connector of the upper level extension base unit Disconnecting procedure To disconnect the extension cable loosen and remove the fixing screws and then disconnect...

Page 24: ...of the module s on the main base unit Current consumption of the module s on the Q5 B Current consumption of the module s on the A1S5 B Current consumption of the QA1S6ADP S1 n 1 Symbol Description I Rated current of the power supply module on the main base unit I0 Current consumption of the module s mounted on the main base unit I1 to I3 Current consumption of the modules mounted on the extension...

Page 25: ... and the extension base unit n th level V1 Voltage drop across the extension cable between the main base unit and the extension base unit 1st level Vn Voltage drop across the extension cable between the extension base unit n 1 th level and the extension base unit n th level R1 Resistance value of the extension cable between the main base unit and the extension base unit 1st level Rn Resistance val...

Page 26: ...upply power to the system where the QA1S6ADP S1 is used in either of the following way Simultaneously turn on the power supply modules on the main base unit and extension base unit Turn on the power supply module on the main base unit first and then turn on the power supply module on the extension base unit Extension level Voltage drops across the QA1S6ADP S1 and extension cables 1st level V1S V1 ...

Page 27: ...25 7 EXTERNAL DIMENSIONS The external dimensions of the QA1S6ADP S1 are shown below When an extension cable is connected Unit mm Unit mm 62 130 78 5 Power supply module Extension cable 130 93 6 128 ...

Page 28: ...26 APPENDIX Appendix 1 Marking and Information Disclosure for the Restriction on Use of Hazardous Substances in Electrical and Electronic Products Required by the New China RoHS ...

Page 29: ...27 MEMO ...

Page 30: ...ber 2016 IB NA 0800539ENG B Descriptions are revised due to compliance with the new China RoHS This manual confers no industrial property rights or any rights of any other kind nor does it confer any patent licenses Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual ...

Page 31: ......

Page 32: ...No 12 Jakarta Pusat 10340 Indonesia Tel 62 21 3192 6461 MITSUBISHI ELECTRIC INDIA PVT LTD Pune Branch Emerald House EL 3 J Block M I D C Bhosari Pune 411026 Maharashtra India Tel 91 20 2710 2000 USA MITSUBISHI ELECTRIC AUTOMATION INC 500 Corporate Woods Parkway Vernon Hills IL 60061 U S A Tel 1 847 478 2100 Turkey Sales office Tel Country Region Sales office Tel Country Region Mexico MITSUBISHI EL...