Mitsubishi Daiya RK71CE-S User Manual Download Page 9

– 8 –

Temperature adjustment during AUTO

Air temperature adjustment is possible even during automatic operation. There are 6 levels of adjustment possible with the 

 button or the 

 button.

AUTO mode operation procedure

Automatically selects the operation mode (HE type: HEAT, DRY, COOL/CE type: COOL, DRY) depending on the room temperature when switched on.

Air flow direction adjustment

procedure. 

 Page 10

1

When a change in temperature is desired.
Aim the remote control at the air-conditioner.

Press the 

 or 

 button.

Air is not blown out during the op-
eration.

 Page 20

If you don’t want the AUTO mode program, change to
COOL,HEAT, DRY or FAN instead of AUTO.

 Page 9

AUTO mode can be
operated by simply
pressing the ON/OFF
button.

To stop:

Press the ON/OFF button.

Each time the 

 button is pressed, the switch over occurs in the following order

–6 

 –5 

 ............ –1 

 ±0 

 +1 ............ +6.

When +6 is indicated, even if the 

 button is pressed, the indicator does not change.

Each time the 

 button is pressed, the switch over occurs in the following order

+6 

 +5 

 ............ +1 

 ±0 

 –1 ............ –6.

When –6 is indicated, even if the 

 button is pressed, the indicator does not change.

When the unit is not in AUTO mode:
Aim the remote control at the air-conditioner.

Press MODE button.

Move the [

 mark] to the 

(Auto) position.

If the air-conditioner is not operating

Press the ON/OFF button.

1

2

When it is a little cold

Press the 

 button.

When it is a little hot

Press the 

 button.

Operation capacity by your choice

FAN SPEED

Set automatically by microcomputer

AUTO

Powerful operation with high capacity

HI

Standard operation

MED

Energy-saving operation

LO

About FAN SPEED

You can choose the capacity of your air-conditioner when heating, cooling or fan.

Aim the remote control at the air-conditioner.

Press the FAN SPEED button.

Move the [

 

mark] to the desirable fan speed position.

AUTO

HI

MED

LO

NOTE

RKW012A202_En.p65

05.2.23, 10:53

8

Summary of Contents for RK71CE-S

Page 1: ...t em conformidade com a Directiva EMC 88 336 CEE e a Directiva LV 72 23 CEE EMC 88 396 LV 73 23 USER S MANUAL MITSUBISHI DAIYA ROOM AIR CONDITIONER RKW012A202 ENGLISH MANUEL DE L UTILISATEUR CLIMATISE...

Page 2: ...s and features 4 Name of each part and its function 5 Operation and indication section for remote control 7 AUTO mode operation procedure 8 Temperature adjustment during AUTO 8 About FAN SPEED 8 COOL...

Page 3: ...cipal water pipe light ning conductor or telephone earth cable Incorrect installation of the earth cable may produce an electric shock Depending on the place of installation a circuit breaker may be n...

Page 4: ...could cause an electric shock fire etc If you notice anything abnormal smell of burning etc stop the system turn off the power switch and consult your dealer Continued use of the system in abnormal ci...

Page 5: ...or SLEEP ON and OFF They can be set as desired Page 13 When using the timer to switch on the sys tem should become operational shortly be fore the set time depending on the room temperature so that th...

Page 6: ...ft right air flow adjustment louver Page 10 Up down air flow direction adjustment flap Page 10 Air outlet Air blows out of here Unit operation switch Room temperature detector Natural enzyme filter Ac...

Page 7: ...r inlet panel for internal cleaning or others open the panel by 80 degrees and then pull it to this side In emergencies this button can be used for turning on off the unit when re mote control is not...

Page 8: ...er OFF timer and SLEEP operation RESET switch Switch for resetting microcomputer Page 16 Indication section TEMPERATURE indicator Indicates set temperature Does not indicate temperature when operation...

Page 9: ...curs in the following order 6 5 1 0 1 6 When 6 is indicated even if the button is pressed the indicator does not change Each time the button is pressed the switch over occurs in the following order 6...

Page 10: ...Inside humidity exceeding 80 may result in condensation forming on the surface of the indoor unit leading to water drips Characteristics of HEAT mode operation Mechanism and capacity of HEAT mode ope...

Page 11: ...opped Swing Multi directional Air Flow up down air scroll and left right air scroll Activating both up down air swing and left right air swing at the same time results in a multi directional air flow...

Page 12: ...of ten minutes 1 00 1 10 Each time the button is pressed the indicator is switched in the order of 0 00 23 50 23 40 Units of ten minutes 23 00 22 50 Set at 22 30 3 The unit stops automatically at the...

Page 13: ...edures on page 11 Set to ON TIMER operation setting Set by the above mentioned ON TIMER operation procedure Set to The setting of the lighting of the timer light yellow of this unit is complete h Afte...

Page 14: ...e timer operation is set on the basis of the present time so please set it correctly 1 3 Changing of set time Set a new time by using the OFF TIMER or ON TIMER button About Amenity facilities Amenity...

Page 15: ...vailable during the dehumidify ing and the program timer operations During ON timer operation HIGH POWER operation will start when the ON time is reached When the following operations are conducted HI...

Page 16: ...ogram OPERATION MODE AUTO FAN SPEED AUTO AIR FLOW AUTO Operation starts by pressing the unit ON OFF button it stops if you press the button again Unit ON OFF button Power blackout auto restart functio...

Page 17: ...reset switch with the tip of a ballpoint pen 1 2 3 Attention to the and marks Press the reset switch with the tip of a ballpoint pen 4 Are the batteries running down Replacing the batteries above Rep...

Page 18: ...is once every two week Don t use the following articles Hot water 40 C or more It may deform or discolour the unit Petrol paint thinner benzine or polishing agents etc They may deform or scratch the...

Page 19: ...natural enzyme filter should be replaced after about 1 year of use However the actual replacement period may vary depending on the conditions in which the filter is used Remove the photocatalytic was...

Page 20: ...cial purpose tools are required Suitable installation position Is there any obstruction in front of the indoor unit preventing proper ventilation and functioning Don t install the unit in any of the f...

Page 21: ...ve stopped or after switching off the power during operation to protect the unit The three minute protection timer in the microcomputer automatically starts up again Please wait for three minutes If t...

Page 22: ...omes damaged ask your dealer or a qualified engineer to install the replacement to avoid accidents Outdoor heat exchanger fluid pipe sensor error Outdoor temperature sensor error Broken outdoor sensor...

Page 23: ......

Reviews: