![Mitel TA7108 Hardware Installation Download Page 7](http://html.mh-extra.com/html/mitel/ta7108/ta7108_hardware-installation_1807028007.webp)
TA7104 /7108 Hardware Installation
155/1531-ANF 90114 C 2017-03-08
4
Table 2 describes the indicators on the front panel of the TA7104.
Table 2:
TA7104/7108 Front LEDs
LED
Description
1.
Ready
When lit, the TA7104/7108 is ready to initiate or receive a call. The unit does not have
to be registered to a server.
2.
In-Use
When lit, at least one of the FXS/FXO lines is in use.
3.
ETH2
Provides the state of the network connected to the
ETH2
connector.
4.
ETH1
Provides the state of the network connected to the
ETH1
connector.
5.
Power
When lit, power is applied to the TA7104/7108 .
Rear Connectors
The TA7104/7108 has several connections that must be properly set. Figure 2 shows the rear panel of
the TA7104.
Standards Supported -
ITU-T I.430 Basic user-network interface - Layer 1 specification (section 9).
Figure 2:
TA7104 Rear Panel Connectors
Table 3
describes the rear panel connections (from left to right).
Connection
Description
1.
Power connector
External 12 Vdc power supply. The TA7104/7108 uses
• a 1.5A power supply.