background image

58/1531-ANF 901 43 Uen E1  2016-03-18

T941AM8 A

LARM

 M

ODULE

 - I

NSTALLATION

 G

UIDE

5

2.1 INSTALLATION TOGETHER WITH OTHER UNITS

Figure 5. Mounting two units together.

1

Remove upper and lower covers. The lower rectangular covers are used to 
fasten units to each other (1).

2

Fasten the module with three screws; see 

figure 3

.

1

1

Summary of Contents for T941AM8

Page 1: ...T941AM8 ALARM MODULE INSTALLATION GUIDE ...

Page 2: ...editions of it may be issued to incorporate such changes No part of this document can be reproduced or transmitted in any form or by any means electronic or mechanical for any purpose without written permission from Mitel Networks Corporation TRADEMARKS The trademarks service marks logos and graphics collectively Trademarks appearing on Mitel s Internet sites or in its publications are registered ...

Page 3: ...ave transient protection and can be programmed for making or breaking contacts Figure 1 The Alarm Module Supply voltage 12 5 V DC 10 Current consumption max 150 mA 100 mA for all inputs For selection of input connection see 7 Connection of Alarm Inputs for Voltage Free Make Break Delivery includes T941AM8 Modular system bus cable Tools etc required Screwdriver Screws for installation Soldering iro...

Page 4: ... MODULE INSTALLATION GUIDE 3 1 1 CIRCUIT BOARD OVERVIEW Figure 2 The circuit board of the Alarm Module ICO1 ICO2 8 1 1 8 4 1 2 1 6 1 J05 J07 J09 J04 SWO1 SW02 S04 LEDO1 IC03 S03 J08 S06 S13 1 8 LEDO2 S14 S05 J01 J02 J06 J03 S01 S02 1 6 LED10 LED03 RE01 ...

Page 5: ...alarm module Figure 3 Mounting dimensions for the Alarm Module Note To facilitate service after the unit is installed we recommend a free space of about 50 mm above and 150 mm below the unit Use a screwdriver or similar to release the cover by applying a light pressure to the two snap catches 1 and remove the cover 2 Figure 4 Releasing the cover of the Alarm Module 9 9 275 56 5 188 5 65 130 112 Di...

Page 6: ... INSTALLATION GUIDE 5 2 1 INSTALLATION TOGETHER WITH OTHER UNITS Figure 5 Mounting two units together 1 Remove upper and lower covers The lower rectangular covers are used to fasten units to each other 1 2 Fasten the module with three screws see figure 3 1 1 ...

Page 7: ...dress must not be 00 nor the same as any other 900 unit address Figure 6 Addressing switch on the Alarm Module Note When connected to the Central Portable Device Manager CPDM the module address has to be in the range 01 to 0F For information about how to distribute alarms from the CPDM to the Alarm Module see Installation and Operation Manual CPDM SW01 OFF ON 1 8 ...

Page 8: ...ght sections of the address switch The eight sections are divided into two groups each with four sections 1 4 and 5 8 Sections 5 8 select the first most significant hex digit and sections 1 4 select the second hex digit Figure 7 Setting the address of the Alarm Module 1 8 2 5 6 8 ON OFF 5 6 8 switches 1 4 second hex digit D switches 5 8 first hex digit 4 1 3 4 2 1 3 4 7 7 1 8 4 5 ...

Page 9: ...break off a suitable section 2 Run the wiring out through the partition Wiring can be run three ways from the Alarm Module Figure 9 How to run cables from the Alarm Module Remove the rectangular pieces and run the cabling out through the side 1 Break off sections at short side of case and run the cabling downwards 2 Run the cabling through the round holes at the bottom of the case 3 Secure the wir...

Page 10: ...odular bus cabling to J01 and J02 1 or if required Connect two wire connection to J03 screw 5 and 6 2 see figure below Figure 11 Connection of system bus with twisted pair and supply voltage Note The data lines are polarised Use only twisted pairs for two wire connections 1 2 3 4 5 6 1 2 1 J03 4 5 BUS 1 6 BUS 2 3 1 12V 2 GND Supply voltage in Supply voltage out System bus ...

Page 11: ...58 1531 ANF 901 43 Uen E1 2016 03 18 T941AM8 ALARM MODULE INSTALLATION GUIDE 10 6 CONNECTION OF SUPPLY VOLTAGE Supply voltage is connected to screw 1 and 2 of screw connector J03 see figure 11 ...

Page 12: ...is can be taken from J03 3 and 4 However for galvanic isolation an external power supply must be connected to J09 Figure 12 Connection of alarm inputs 1 2 3 4 5 6 J07 7 8 1 EXTERNAL 12VDC 2 EXTERNAL 12VDC J09 ALARM INPUT 1 ALARM INPUT 2 ALARM INPUT 3 ALARM INPUT 4 1 2 3 4 5 6 J08 7 8 ALARM INPUT 5 ALARM INPUT 6 ALARM INPUT 7 ALARM INPUT 8 Alarm input 1 Alarm input 2 Alarm input 3 Alarm input 4 Ala...

Page 13: ... indicator on the Alarm Module No light No power check power supply Hardware fault contact your dealer Slow blink 0 5 Hz Program error Restart the unit by switching the power off and on Fast blink 0 8 Hz Communication error Check bus polarity and addressing of the unit One blink every fourth second Unit in test mode Contact your dealer Activate an input and check that the handsets respond correctl...

Page 14: ...3 18 T941AM8 ALARM MODULE INSTALLATION GUIDE 13 9 PROGRAMMING System settings in the Alarm Module are factory set Default settings are Information is transmitted to the Basic Alarm Manager in the CPDM when an input is opened or closed ...

Reviews: