59
Basic Installation
ONS/CLASS and LS/CLASS ports
Connect the LS CLASS trunks and any ONS phones to the line ports on
the back of the controller using standard 4-conductor cables with RJ-11
connectors.
After connecting the LS trunks, use the Line Quality Test to program the
audio configuration settings. For more information, see “Running the Line
Quality Test for LS Trunks” on page 114.
Refer to the following table for circuit assignments and default numbering
for ONS phones.
Table 6: ONS & LS Circuit Assignments
Circuit
PLID
Default
DN/Line
Number
Circuit
PLID
Default
DN/Line
Number
An
al
og
Ma
in
Bo
ar
d
ONS 1
1/13/3
200
An
a
log
O
p
ti
on
Boa
rd
ONS 1
1/13/19
--
ONS 2
1/13/4
201
ONS 2
1/13/20
--
ONS 3
1/13/5
202
ONS 3
1/13/21
--
ONS 4
1/13/6
203
ONS 4
1/13/22
--
LS 1
1/13/7
1
LS 1
1/13/13
--
LS 2
1/13/8
2
LS 2
1/13/14
LS 3
1/13/9
3
LS 3
1/13/15
LS 4
1/13/10
4
LS 4
1/13/16
LS 5
1/13/11
5
LS 5
1/13/17
LS 6
1/13/12
6
LS 6
1/13/18
Notes:
1.
Tip and Ring correspond to pins 3 and 4 of the RJ11 connector
respectively.
2.
ONS/CLASS ports do not support high-voltage message-
waiting lamps.
3.
Trunks circuits located at 1/13/7 and 1/13/8 on the AMB and
1/13/13 and 1/13/14 on the AOB are System Fail Transfer (SFT)
trunks. In the event of a system or power failure, the trunks
connect to ONS circuits 1/13/3 and 1/13/4 on the AMB and
circuits 1/13/19 and 1/13/20 on the AOB respectively.
4.
ONS ports are not designed with the necessary safety protection
for off premise connections. ONS ports must not be used to
connect to off premise phones.
Summary of Contents for SX-200 ICP - 1.0 5020
Page 1: ...Release 4 0 CX CXi Controller TECHNICIAN S HANDBOOK ...
Page 9: ...Chapter 1 Introduction ...
Page 10: ...2 SX 200 ICP CX CXi Technician s Handbook ...
Page 24: ...16 SX 200 ICP CX CXi Technician s Handbook ...
Page 25: ...Chapter 2 Basic Installation ...
Page 26: ...18 SX 200 ICP CX CXi Technician s Handbook ...
Page 75: ...Chapter 3 Basic Programming ...
Page 76: ...68 SX 200 ICP CX CXi Technician s Handbook ...
Page 89: ...81 Basic Programming The keys on the 5412 PKM are numbered as follows ...
Page 98: ...90 SX 200 ICP CX CXi Technician s Handbook Figure 10 Administrator Mailbox Menu ...
Page 142: ...134 SX 200 ICP CX CXi Technician s Handbook ...
Page 143: ...Chapter 4 Advanced Installation and Programming ...
Page 144: ...136 SX 200 ICP CX CXi Technician s Handbook ...
Page 183: ...Chapter 5 Routine Maintenance ...
Page 184: ...176 SX 200 ICP CX CXi Technician s Handbook ...
Page 219: ...Chapter 6 Basic Troubleshooting and Repair ...
Page 220: ...212 SX 200 ICP CX CXi Technician s Handbook ...
Page 245: ...Chapter 7 Advanced Troubleshooting and Repair ...
Page 246: ...238 SX 200 ICP CX CXi Technician s Handbook ...
Page 269: ...Appendix A Default Database Values ...
Page 270: ...262 SX 200 ICP CX CXi Technician s Handbook ...
Page 326: ...318 SX 200 ICP CX CXi Technician s Handbook ...
Page 327: ...Appendix B Part Numbers ...
Page 328: ...320 SX 200 ICP CX CXi Technician s Handbook ...
Page 336: ...328 SX 200 ICP CX CXi Technician s Handbook ...
Page 337: ...Appendix C System Cabling ...
Page 338: ...330 SX 200 ICP CX CXi Technician s Handbook ...
Page 343: ...Appendix D Folio Views E Docs Tips ...
Page 344: ...336 SX 200 ICP CX Technician s Handbook ...