Original Instructions: 001059 DRAFT
34
Twin-Axis
Sheathing Saw: Maintenance
Pneumatic System
Removing Pressure from the Pneumatic System
Most procedures involving the pneumatic system require the removal of pressure.
Use the following procedure to remove pressure from the system.
1. Turn the switch to the off position and push the blue slide outward so the
lockout/tagout hole is visible.
Figure 5-12: Pneumatic Airflow On and Off Positions
2. Lockout/tagout through the hole on the slide. See Figure 1-5 on page xvi
for example.
Maintaining the Filter / Regulator
Adjusting the Pressure on the Regulators
The pressure adjustment knob on a the regulator controls the operating pressure
for a pneumatic system. The
Twin-Axis
Sheathing Saw utilizes two pressure
regulators that must be set at different pressures.
• Low Pressure Regulator: operating pressure should be set at 30 psi.
• High Pressure regulator: operating pressure should be set at 65 psi.
Use the following procedure to adjust operating pressure.
1. Push the blue tab inward to unlock the adjustment knob. See Figure 5-13
!
CAUTION
HIGH PRESSURE HAZARD.
Bleed all pressure from pneumatic lines before performing
maintenance on pneumatic components.
Pressurized components may move suddenly or vent air to
atmosphere, causing injury.
On
Position
Off
Position
Push Blue Tab Out
for Lockout/Tagout