NOTES FOR INSTALLATION 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

AVOID IMPEDIMENTS 

AVOID DIRECT SUNLIGHT 

AVOID 
INSTALLABLE 
SURFACE 

AVOID THAT A RECEIVER CAN 
SEE MORE TRANSMITTERS 

DISTANCE OF DETECTION 

DISTANCE OF DETECTION 

ITEM 

RAY 
DISPERSION 
DIAMETER 

RAY DISPERSION DIAMETER 

EX

A

MP
LE

 

 O

F I

N

ST

A

LL

A

TIO

N

 H

EI

G

H

INSTALLATION - ALIGNMENT - FREQUENCY CHANGE - SENSITIVITY ADJUSTMENT 

 
1. 
2. 
 
 
 
1. 
 
2. 
 
 
 
 
 
3. 
 
 
 
 
 
 
 
 
 
 

 

1. 
 
2. 

INSTALLATION 

Fix the barriers so that they are aligned and wire the terminal block. 
Both on the receiver (RX) and on the transmitter (TX) check that all the dip switches are in the OFF position and power the modules. 

ALIGNMENT (SIGNAL LEVEL CONTROL) 

Control the red LED on the receiver module, if it is off and the buzzer does not sound (to enable the buzzer, set dip switch 9 to 
ON) the barriers are aligned. If the LED is on and the buzzer sounds, follow the procedure below: 
On the receiver, set dip switch 8 to ON and then dip switch 7 to ON, 

NOT BEFORE 7 AND THEN 8. 

Note: this is the procedure to follow even if you only want to check the signal level with aligned modules. 

A signal value will be shown on the display, then orient the receiver's optical unit in the direction of the transmitter and vice 
versa until the LED on the receiver module is off and the buzzer stops ringing. 
The values are to be considered optimal if included between 2.6 to 3.6 V, if the LED goes off even below 2.6 V it means that the 
barriers are communicating, if possible, however, try to reach a value between 2 anyway, 6 and 3.6 V. 
For vertical adjustments, act on the adjustment screw, while for horizontal adjustments, rotate the bracket (see IMAGE 1). If 
necessary, use the viewfinder to help you (see IMAGE 2). 

Once the modules are aligned, set dip switch 8 to OFF and dip switch 7 to OFF, NOT BEFORE 7 AND THEN 8. 
 
 
 
 
 
 
 

 

FREQUENCY CHANGE  

To change the frequency which by default is 1 (dip switches 1,2 and 3 in OFF), 
follow the procedure below: 

First on the RX module and then on the TX module, using the dip switches 1,2 and 3 
set the frequency, see the table on the side for the 8 possible combinations. 

First on the RX module and then on the TX module confirm the frequency 
by setting dip switch 7 to ON and after a second repositioning it in OFF. 

ATTENTION: NEVER LEAVE DIP SWITCH 7 ON. 

 

SENSITIVITY ADJUSTMENT: 

 

Turn the trimmer                         located on the right side of the receiver to adjust the sensitivity. 

OFF   ON    OFF   ON    OFF   ON    OFF   ON 
 
OFF   OFF   ON    ON    OFF   OFF   ON    ON 
 
OFF   OFF   OFF   OFF   ON    ON    ON    ON 

FREQUENCY NUMBER (FROM 1 TO 8) 

DIP

 

1      2      3      

 

4      

  

5       6      7      8   

IMAGE 2 

IMAGE 1 

MIN 

MAX 

VIEWFINDER POINT OF VIEW

 

        INSTALLATION 

        ALIGNMENT (SIGNAL LEVEL CONTROL) 

        FREQUENCY CHANGE  

        SENSITIVITY ADJUSTMENT 

GEMINI 30 
GEMINI 60 
GEMINI 100 

WARNING: THE PROGRAM FOR THE CORRECT OPERATION OF THE BARRIERS IS LO 0.1 (STANDARD SETTING) 

The set program is displayed alternately with the set frequency number. If the barriers are set to another program number (e.g. 0.2-0.3, etc.), set all the dip switches to OFF, 

then position the dip switch 7 to ON and then also the dip switch 8, NOT DIFFERENTLY. Wait a few seconds then set dip switch 7 to OFF and then also dip switch 8, NOT DIFFERENTLY. 

Summary of Contents for GEMINI

Page 1: ... a giungere a 0 8 V il modulo RX attiva l uscita fault allarme anti fog quando il segnale raggiunge invece 0 4 V il modulo RX attiva l uscita di allarme MADE IN ITALY GEMINI Rev 07 10 2020 MITECH srl si riserva di modificare i dati senza preavviso Pagina 1 di 2 GEMINI è la mini barriera all infrarosso attivo a doppia lente dalle dimensioni molto contenute Precablata e pronta per l installazione è ...

Page 2: ...i verticali agire sulla vite di regolazione mentre per quelle orizzontali intervenire ruotando la staffa vedere IMMAGINE 1 Se necessario aiutarsi con il mirino vedere IMMAGINE 2 Una volta allineati i moduli posizionare in OFF il dip switch 8 e di seguito in OFF il dip switch 7 NON VICEVERSA CAMBIO FREQUENZA Per cambiare la frequenza che di default è su 1 dip switch 1 2 e 3 in OFF seguire la seguen...

Page 3: ...Anti flog function where signal strenght decrease slowly to 0 8 V the detector will active anti flog alarm fault output when signal decrease ti 0 4 V will active alarm MADE IN ITALY GEMINI Rev 07 10 2020 MITECH srl reserves the right to change the information in this document without warning Page 1 of 2 GEMINI is the mini IR barrier with dual lens with and small dimensions Ready for installation i...

Page 4: ...sidered optimal if included between 2 6 to 3 6 V if the LED goes off even below 2 6 V it means that the barriers are communicating if possible however try to reach a value between 2 anyway 6 and 3 6 V For vertical adjustments act on the adjustment screw while for horizontal adjustments rotate the bracket see IMAGE 1 If necessary use the viewfinder to help you see IMAGE 2 Once the modules are align...