1
.
The
master
code
is
used
to
access
programming
mode
.
(
Default
master
code
=
1234
)
The amount of digits used in the master code can be anything between 4 and 8 digits.
NB
!
The number of digits used for the master code will determine the length of all other codes.
I.e. The default master code is 1234 so therefore all user codes will be 4 digits long.
Setup
a
new
master
code
: (
Default
=
1234
)
Current
Master
Code
Current
Master
Code
(
chime
tone
up
)
*
00
New
4
to
8
digit
Master
Code
#
(
chime
tone down)
I
.
e
.
To
change
the
master
code
to
4321
:-
1234
1234
*
00
4321
#
Setup
user
codes
01
to
19
that
activate
the
lock
relay
:
(
User
01
default
=
3333
)
Type
in
the
following
:
Master
Code
Master
Code
(
chime
tone
up
)
*
two
digit
user
number
New
User
Code
(
chime
tone
up
)
I
.
e
.
To
change
user
01
to
8282
without
exiting
program
mode
afterwards
: -
1234
1234
*
01
8282
Repeat
for
additional
users
or
type
#
to
exit
programming
mode
(
Chime
tone
down
)
.
Type
in
the
following
:
Deleting
a
user
code
:
Type
in
the
following
:
Master
Code
Master
Code
(
chime
tone
up
)
*
00
#
to
clear
all
users
and
default
user
01
to
3333
Or
Master
Code
Master
Code
(
chime
tone
up
)
*
2
digit
user
number
#
to
clear
an
individual
user
.
Setup
type
or
pulse
length
of
Lock
relay
:
(
Default
=
5
sec
.)
Type
in
the
following
:
Master
Code
Master
Code
(
chime
tone
up
)
*
20
00
for
latch
mode
or
01
sec
for
1
sec
,
02
for
2
sec
99
for
99
sec
#
to
exit
programming
mode
.
(
Chime
tone
down
)
1
Setup
code
to
activate
the
Auxiliary
relay
:
(
Default
none
)
Type
in
the
following
:
Master
Code
Master
Code
(
chime
tone
up
)
*
40
New
Auxiliary
Code
(
chime
tone
up
)
I
.
e
.
To
setup
Aux
relay
code
to
2222
without
exiting
program
mode
afterwards
:-
1234
1234
*
40
2222
Continue
to
additional
programming
or
type
#
to
exit
programming
mode
(
Chime
tone
down
)
.
4
Enter programming mode
Change master code
Set user codes 01
~
19
(
Lock output relay
only
)
Set user codes 20
~
39 and 41
~
99
(
lock
output relay only
)
Set user code 40
(
Aux output only
)
Select Lock relay mode or pulse length
.
Activating incorrect code input lockout
(
20
digits or 5 attempts results 30sec lockout
)
Delete a user code or all user codes
. (
If
deleting all user 01 defaults to 3333
)
Activating bypass mode
.
De
-
activate bypass mode
.
Setup bypass code
Disable alarm output mode
Select alarm output activates on door forced
open condition
Select alarm output activates on tamper
switch
Select alarm output activates on both door
forced and tamper switch
Select Alarm output active time
Select Aux ouput mode or pulse length
Disable Aux ouput
Allocate door monitor to work with Aux
output
Activate Aux output when incorrect code is
entered
Activate Aux output when
*
key is pressed
(
Doorbell function
)
Activate Aux output when tamper is activated
Activate Aux output when door is forced open
Activate Aux out at same as lock output
Aux ouput only activates when Aux code is
entered
Factory default
Place jumper across restore pins
Power up
On continuous chime remove jumper and replace it in normal operation position
.
Need Action
Response
Buzzer LED
Master code
-
Master code
*
00
-
new master code
(
4
-
8 digits
)
Note the number of digits the master
is set to will be the number of digits each user code must be
.
*
01
~
19
-
new unique user code
(
Same length as master code
)
*
6
-
2 digit user number
-
new unique user code
(
Same length as master code
)
*
40 new unique aux user code
(
Same length as master code
)
*
20
-
00
=
latch mode or 01 sec for 1 sec
,
02 for 2 sec
99 for 99 sec
*
51
*
50
-
00 for all
,
01 for user 1
,
02 for user 2
.
99 for user 99
.
*
52
-
1
*
52
-
0
*
54
-
new unique bypass code
*
55
-
0
*
55
-
1
*
55
-
2
*
55
-
3
*
56
-
001 for 1 sec
,
002 for 2 sec
..
999 for 999 sec
.
*
58
-
00
=
latch mode or 001 for 1 sec
,
002 for 2 sec
..
999 for 999 sec
.
*
57
-
0
*
57
-
1
*
57
-
2
*
57
-
3
*
57
-
4
*
57
-
5
*
57
-
6
*
57
-
7
Yellow
Chime tone
up
No chime
tone
Chime tone
up
Chime tone
up
Chime tone
up
Chime tone
up
Chime tone
up
Chime tone
up
Chime tone
up
Chime tone
up
Chime tone
up
Chime tone
up
Chime tone
up
Chime tone
up
Chime tone
up
Chime tone
up
Chime tone
up
Chime tone
up
Chime tone
up
Chime tone
up
Chime tone
up
Chime tone
up
Chime tone
up
Chime tone
up
Continuous
chime
Yellow
Yellow
Power down
ADVANCED
PROGRAMMING
OPTIONS
.
Summary of Contents for MKP-1101
Page 1: ...MKP 1101 ...
Page 2: ......