5
INFORMATION:
In order for the device to function continuously without malfunctions and to have
a long life, it should be operated within the parameters stated in this manual.
SET
MENU
PB
[ 0020
0
C]
TI
[ 0240 s]
TD
[ 0060 s]
CTC
[ 0015 s]
CT
[ 0015 s]
PBC
[ 0020
0
C]
Heating
control time
setting
Cooling
control time
setting
PBC cooling
proportional
band setting
Heating
proportional
band setting
Integral time
setting
Differential
time setting
1 PB
2 TI
3 TD
4 PBC
5 CT
6 CTC
Control
Control
MIT-TRG-S Series Mold Heater can be adjusted up to a maximum temperature of 120 °C.
WARNING: Check the direction of rotation of the pump.
5. The device automatically adjusts the mold temperature with an accuracy of ± 1 °C