25
Should the water block be jammed, you will
have
to
re-prime
it
as
explained
below :
4
3
Water block OFF
Water
flow w
ay
5
Water block ON
5.
Screw the connector back on the water
block.
6.
Turn on the water supply.
7.
Press the cold water button on the control
panel.
1.
Turn off the water supply.
2.
Press the cold water button on the control
panel to remove residual pressure in the water
system.
3.
Unscrew the plastic connector.
4.
Press the red button to unjam the water
NB:
The water block is pre-adjusted in position 2 to be jammed after a 10 litres
continuous use. Beyond this quantity, the water supply system is blocked.
Water block unjamming
Non-return valve cleaning
Located at the back, the non-return valve is an efficient systeme to keep
water clear.
Control the proper functioning of the non-return valve at least one a year:
- Turn off the water supply
- Open the purge (1)
- Control the non return of the water.
1
General checking
Control the water circuit
Verify and control the cooling unit
Control the water temperature and proceed to an adjustment if necessary
Verify the érifier les water proofing