background image

 

 

     

 

 

Page | 16

 

WARRANTY & DISCLAIMER 

 

LIMITED WARRANTY 

The manufacturer of the FumeAway Extractor warrants the original purchaser, that the 
product will be free from defects in materials and workmanship for a period of (1) year. 
This warranty includes fan, gauge, electrical and mechanical components. Excluded 
are consumable filters, normal wear, and tear on finished surfaces. Any parts that are 
determined to be defective by Mistaway are to be returned shipping prepaid and will be 
repaired or replaced at Mistaway and shipped back to the customer.  

 

DISCLAIMER 

FUMEAWAY MANUFACTURER MAKES NO OTHER WARRANTY, EXPRESSED OR 
IMPLIED, AND MAKES NO WARRANTY OF

 

MERCHANTABILITY OR FITNESS FOR 

A PARTICULAR PURPOSE. The customer is solely responsible to determine if the 
FA200 Extractor is suitable for their specific application. It is the customers 
responsibility to determine if this equipment is applied correctly to their particular 
application, installed correctly, and maintained properly. Customer must ensure that 
proper safety measures are in place for each specific application. The FA200 is not 
designed to be a single solution and additional PPE may be required. The customer 
should contact a safety consultant to perform a hazard assessment and use OSHA 
guidelines on how to implement, test, and maintain an effective fume control and safety 
program per their application to protect the safety of their workers. 

The FA200 is for 

Industrial or Commercial Use Only.

 

Manufacturer of this equipment shall not be held liable for direct or consequential 
damages resulting from improper installation, application, maintenance, training, or 
improper use. 

Any liability for consequential or incidental damages from the use 

or misuse of this product that results in personal injury or property damage is 
expressly disclaimed.

 

 

Mistaway reserves the right to change designations and or specifications without 
notice.  

See our website for the most up-to-date instructions and product information at: 

http://www.mistawaycollector.com

 

Summary of Contents for FumeAway FA200

Page 1: ...Manufactured by Mistaway Filtration Systems 14 Industrial Park Rd Troy NY 12180 www mistawaycollector com User Manual FumeAway Fume Extractor MODEL FA200 For Industrial or Commercial Use Only...

Page 2: ...5 Laser Cutting Etching 5 Soldering Electronics Manufacturing 5 Additional Applications 5 SECTION 3 SPECIFICATIONS 6 SECTION 4 UNPACKING 7 SECTION 5 INSTALLATION INSTRUCTIONS 8 Direct Machine Applicat...

Page 3: ...to protect the safety of their workers Do not modify the unit to perform any task that it was not designed for Do not use the unit for welding or any applications that could create a spark without th...

Page 4: ...OR FUMES 3 IF USED WITHOUT THE EXTRACTION ARM A SPARK ARRESTOR OR SPARK TRAP SHOULD BE INSTALLED IF SPARKS COULD BE PRESENT IN THE AIR STREAM 4 ALWAYS HAVE A PROPERLY RATED FIRE EXTINGUISHER NEARBY NE...

Page 5: ...dards Certain operations such as cutting welding soldering and brazing of metals can produce toxic fumes containing a wide variety of hazardous substances This unit is designed to be a PART of a weldi...

Page 6: ...park arrestor is required for this application It is up to the customer to install a proper spark arrestor before the intake of the FA200 Soldering Electronics Manufacturing The FA200 Extractor can be...

Page 7: ...60Hz 1 phase 101 Watts Max 0 9 amps Air Flow 190 CFM Variable Speed Noise 62 dB 6ft Power Cord 5 standard 3 prong plug NEMA 5 15P Dimensions 15 x 15 x 18 1 Weight with supplied filters Weight Approx...

Page 8: ...Base Unit arrives assembled and ready to use The unit is comprised of the components listed below Item Number Description QTY 1 Base Assembly 1 2 1200 HEPA 95 C 95 efficiency at 0 3 m 1 3 Blower Assem...

Page 9: ...ple is shown below WARNING The optional Extraction Arm includes a spark guard screen within the assembly If the unit is used without the optional Extraction Arm a Spark Trap or Spark Arrestor is requi...

Page 10: ...ility of a fire The Extraction Arm will arrive semi assembled and the customer will just need to mount it to the unit The packing list and instructions for assembly are shown below PACKING LIST Item N...

Page 11: ...Page 10 Extraction Arm Assembly...

Page 12: ...C the air flow is decreased considerably o At this point the filter should be replaced o See Section 7 for instructions Caution If the filter status reads in the Dirty range fumes are not being extra...

Page 13: ...Page 12 SECTION 7 FILTER REPLACEMENT...

Page 14: ...Page 13...

Page 15: ...Page 14...

Page 16: ...ions shown in Section 7 2 Diagnose source of obstruction and fix check machine ducting for clog 3 Contact MistAway Support Fumes are not being evacuated 1 The intake hood is not close enough to the ap...

Page 17: ...heir particular application installed correctly and maintained properly Customer must ensure that proper safety measures are in place for each specific application The FA200 is not designed to be a si...