CHARGER

AC INPUT

REM

BTS

Wiring box cover must be in place during

use to reduce risk of injury to persons

PASS-THRU

AC INPUT

INVE

RTER

AC OUTPUT

AC

IN

AC

OUT

AC GROUNDS

(BEHIND COVER)

WARNING:

 INCORRECT BATTERY PO

LA

RIT

Y W

ILL

 C

AU

SE

 D

AM

AG

E T

O

 U

N

IT.

N1

L1

N2

L2

N

L1

L2

  

  

Xantrex Battery

built-in

GFCI kit

Neutral

Line

AC IN

AC OUT

busbar

busbar

 

vehicle

engine

vehicle second alternator

neg(–)

pos(+)

See 

Table 1

 for a 

list of approved 

fuse options.

DC load branch 

circuit breaker or 

fuse

service disconnect

BMS

neg(–)

pos(+)

Secure the DIN connectors 

together with a tie wrap.

ON/OFF RESET button

BTS connector

pressure balancing valve

AC IN

AC OUT

20.4-21.7 Nm

1.5-1.7 Nm

15.82 Nm

all studs

15.82 Nm

all studs

9.02 Nm

9.02 Nm

21.47 Nm max

fuseholder

Consult alternator manufacturer for torque values

3-inch clearance

3-inch clearance

wire nut 

GB-6 

(76B)

wire nut 

GB-6 

(76B)

to GFCI 

line side

15

System Diagram for Power Connection

EQUIPMENT DAMAGE

The system diagram is for information and illustration purposes only. Always use a professional 

installer that satisfies the requirements for a qualified personnel.

Failure to follow these instructions can result in damage to equipment.

NOTE

:

• The diagram is for information and illustration purposes only. Images are not-to-scale.

• The system diagram is not intended to guide the actual placement of equipment. 

• Read and follow 

“DC Cable and Fuse Requirements”

 section.

NOTE

:

To add a SOLAR kit, 

see the Xantrex Solar 

Kit Guide, document 

part number 

975-0808-01-01.

DC – cable
DC + cable
Chassis ground

LEGEND

black = LINE/HOT

AC cable white = NEUTRAL

green/bare = GROUND

Ground

DC negative

disconnect

Heating mat adhered to battery case

DC load

15A DC

fuse (max)

2-pole

DC disconnect

(recommended)

Combiner

Chassis IGN (red)

Solenoid Positive (blue)

Lithium Battery (yellow)

Ground (black)

Chassis Battery

DC Bus

Combiner Wiring Diagram

MEG100

100A FUSE

To IGN

control

Only required 

on 51V 

systems.

Heat temp

sensor

solar panel

solar charge controller

15A DC fuse

Reviews: