MISSION CONTROLS Supersilent User Instructions Download Page 3

Setting up:

How to use:

1. Set minimum fan speed on dial 1, set maximum fan 

speed on dial 2. Fans will work between these parameters. 

For the largest operating range, we recommend Min 20% 

and Max 100%.

2. Set target temperature on dial 3.

3. 

Night-Pulse™

 Deactivated = Cap on. Activated = Cap 

off. 

Mains power must be off before activating or deactivating. 

4. Switch on at mains. 

5. Controller will enter a short period of calibration. 

During this time, fans may pulse up and down. After 

approximately 5 minutes, fans will find the right speed.

Plug 

SuperSilent™

 Temperature Controller into 

mains socket. Leave the mains power switched off 

until you have completed setup.

1

Plug input fan into socket 1, and outtake fan

into socket 2.

2

Position Temperature Sensor inside room at canopy height, 

taking care to avoid places where it may take a false 

reading, such as directly under lights, or in front of fan.

3

Position 

Night-Pulse™

 sensor inside room where it can 

detect light. Do not put directly under light. 

4

EN 

Socket 1

Socket 2

INPUT

OUTTAKE

Deactivated 

(Cap on)

Activated 

(Cap off)

(Mains Power 

OFF

 before Deactivating or activating 

Night-Pulse™

)

Dial 1 

(Min Fan Speed) 

Dial 3 

(Temperature) 

Dial 2 

(Max Fan Speed) 

Reviews: