Ductless recirculation is intended for applications where an exhaust duct work is not possible to be installed. 
When converted, the hood functions as a recirculating hood rather than an exhaust hood. Fumes and exhaust 
from cooking are drawn and 

¿

 ltered by a set of optional charcoal 

¿

 lters. The air is then puri

¿

 ed and re-circulated 

back within the home.

We recommend to ALWAYS exhaust air outside of the home by employing existing or installing new duct work, 
if possible. The hood is most effective and ef

¿

 cient as an exhaust hood. Only when the exhaust option is not 

possible should you recourse to converting the hood into a recirculating hood.

When converted to be a recirculating hood, a set of charcoal

¿

 lters are required on top of its standard Metal 

Filter set. Order according to its Part number below. The standard Metal Filters are intended to capture residue 
from cooking and the optional charcoal

¿

 lters help to purify fumes exhausted from cooking for re-circulation.

RECIRCULATING KIT (REQUIRED IF NO DUCTING IS USED)

Kit includes charcoal 

¿

 lters, charcoal 

¿

 lter brackets and air diverter plate.

Hood Model 

 

Part No. 

          Filters in Pkg.

MH00436G 

                          RHRK004S  

     2                                     

1.   Purchase recirculating kit per the part number above

2.   Secure air diverter plate to top support frame. (FIG. H)  Run 6” ducting 

from top of hood and secure to air diverter plate. 

3.  Remove mesh 

¿

 lters from hood. Secure the charcoal 

¿

 lter bracket to the 

inside of the hood behind mesh 

¿

 lters with (4) M3.5 x 8 screws.  Clip 

charcoal

¿

 lters into each charcoal 

¿

 lter bracket opening. (FIG. H) 

4.   Re-install mesh 

¿

 lters.

5.  Charcoal 

¿

 lters  must  be  replaced  after  every  120  hours  of  use  (or 

approximately every 3 to 4 months based on the average of 1 - 2 hrs. of 
daily cooking time). 

Note:

Refer to manual included with recirculating kit for more detailed 

installation instructions.

Charcoal Filter Replacements

Hood Model 

 

Part No. 

          Qty to Order

MH00436G 

 

RHCF001   

   2

DO NOT WASH CHARCOAL FILTERS.  Charcoal 

¿

 lters may need

to be changed more often depending on cooking habits.

Installation – 

Ductless Recirculating

FIG. H

Summary of Contents for MH00436G

Page 1: ...Installation Use and Care Guide 2014 SEP READ AND SAVE THESE INSTRUCTIONS MODEL MH00436G ...

Page 2: ...www build com ...

Page 3: ...ng Height Clearance 6 Ducting Options 7 Hood Specifications 8 Mounting the Hood 9 11 Ductless Recirculating 12 FEATURES CONTROLS Mechanical Controls 13 MAINTENANCE Hood and Filter Cleaning 14 Lights 15 TROUBLESHOOTING 16 WIRING DIAGRAMS 17 LIST OF PARTS AND ACCESSORIES 18 Table of Contents ...

Page 4: ...ONS IN THE EVENT OF A RANGE TOP FIRE OBSERVE THE FOLLOWING a SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT b NEVER PICK UP A FLAMING PAN You may be burned c DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will result d U...

Page 5: ...lation is adequate and in conformance with National Electrical Code ANSI NFPA 70 latest edition or CSA standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances If codes permit and a separate ground wire is used it is recommended that a quali ed electrician determine that the ground path is adequate Do not ground to a gas pipe Check wit...

Page 6: ...ct covers 2 Bottom duct covers 1 Hood body w blower pre installed 1 Canopy glass 2 Aluminum mesh filters 2 50W GU 10 halogen lights 1 6 round damper pre installed MODELS MH00436G PARTS SUPPLIED HARDWARE PACKAGE CONTENTS PARTS NOT SUPPLIED Ducting conduit and all installation tools Cable connector if required by local codes Duct cover extension accessory Recirculating kit accessory 4 3 16 x 8 canop...

Page 7: ...lent number length x used 6 8 Round wall cap with damper 30 Ft x Ft Round wall cap with damper 30 Ft x Ft 7 or 8 Round 900 elbow 15 Ft x Ft 7 or 8 7 or 8 Round 450 elbow 9 Ft x Ft Ft Ft Ft 6 8 Round roof cap 30 Ft x Ft 7 or 8 Round roof cap 30 Ft x Ft Subtotal column 2 Subtotal column 1 Total ductwork Maximum Duct Length For satisfactory air movement the total duct length of a 3 1 4 x 10 rectangul...

Page 8: ... mounted too low could result in heat damage and fire hazard while hoods mounted too high will be hard to reach and will loose its performance and efficiency If available also refer to range manufacturer s height clearance requirements and recommended hood mounting height above range Always check your local codes for any differences Duct cover extension kit available for ceiling heights up to 12 fee...

Page 9: ...ss using the recirculating option Use single wall rigid Metal ductwork only Fasten all connections with sheet metal screws and tape all joints w certified Silver Tape or Duct Tape Some Ducting Options Installation Ducting Options side wall cap w gravity damper Soffit or crawl space Roof Pitch w Flashing Cap ductless recirculating blower housing blower housing blower housing ...

Page 10: ...ions FRONT SIDE TOP of HOOD TOP SUPPORT FRAME top view 10 3 8 23 15 16 35 3 16 25 9 16 24 1 2 3 9 16 10 3 4 2 3 4 11 5 8 4 3 8 Min Ducted 28 Min Recirc 28 Maximum 38 top of electrical box 13 3 4 5 1 6 C L 6 elec k o 8 3 4 3 3 4 4 3 16 5 8 8 8 1 4 ...

Page 11: ... screws 2 screws for each support frame arm FIG A 2 3 Lift support frame assembly up to the ceiling making sure the the word front on the top support frame faces the front of the hood where the controls will be located FIG C The key holes on the top support frame should cover the wood screws previously installed in the ceiling Slide support frame towards narrow end of key holes to lock the frame i...

Page 12: ... installed mounting screws on top of blower housing FIG A 5 on Page 9 with the 4 key holes on the bottom of the support frame FIG F Slide hood towards the narrow end of key holes to lock in place Hand tighten each of the 4 screws to secure hood to bottom of support frame Install 1 4mm x 12mm long safety screw into bottom support frame to further secure the hood FIG F 1 Reinstall mesh filters 8 Inst...

Page 13: ...s 12 Assemble bottom duct covers together over top duct covers using 3 M3 x 6 screws on each side Bottom duct covers will rest on top of the hood body FIG G 3 13 Insert the 2 thin trim pieces into left and right seams of bottom duct covers 1 on each side FIG G 4 14 Insert the 2 thick trim pieces into left and right seams of top duct covers 1 on each side FIG G 5 Note Because less of the top duct c...

Page 14: ...ers help to purify fumes exhausted from cooking for re circulation RECIRCULATING KIT REQUIRED IF NO DUCTING IS USED Kit includes charcoal lters charcoal lter brackets and air diverter plate Hood Model Part No Filters in Pkg MH00436G RHRK004S 2 1 Purchase recirculating kit per the part number above 2 Secure air diverter plate to top support frame FIG H Run 6 ducting from top of hood and secure to a...

Page 15: ... Blower Speed Selection Blower Off The blower will be powered off by pressing Blower Speed Selection Select one of three speed levels by pressing Lights On Off Power lights on and off by pressing 3 Features Controls Mechanical Controls ...

Page 16: ...oth and with the grain Do not use any product containing chlorine bleach Do not use orange cleaners Stainless Steel Mesh Filters The stainless steel mesh filters installed by the factory are intended to filter out residue and grease from cooking They need not be replaced on a regular basis but are required to be kept clean Remove and clean by hand or in dishwasher on low heat Spray degreasing deterg...

Page 17: ...turning bulb counter clockwise Note Bulb does not unscrew it turns 60 degrees stops and falls out If bulbs are difficult to turn due to prolonged use firmly attach a glass suction cup approximately the diameter of the bulb or use a rubber latex glove and turn counter clockwise Replacement bulbs are available at specialty lighting stores Purchase type GU 10 50W halogen For part numbers please turn to...

Page 18: ... D 5 h c t i w s e h t e g n a h C 6 e v i t c e f e d s i h c t i w s e h T 6 The unit is vibrating 1 The blower is not secure in place 1 Tighten the blower in place r e w o l b e h t e c a l p e R 2 l e e h w r e w o l b d e g a m a D 2 3 The hood is not secured in place 3 Check the installation of the hood The blower is working but the lights are not 1 The light bulb plug is disconnected 1 Conn...

Page 19: ...17 Wiring Diagrams MH00436G ...

Page 20: ...ment Parts Light Bulb GU 10 50W each Z0B 0020 Optional Accessories Recirculating Kit RHRK004S Replacement Charcoal Filter RHCF001 Duct Cover Extension up to 12 ceiling RHEX004S To order parts email us at vsupport ventingservices com or call us at 1 888 750 1698 ...

Page 21: ... you are also responsible for all labor costs associated with this warranty Limitations of Warranty OUR OBLIGATION TO REPAIR OR REPLACE AT OUR OPTION SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY WE SHALL NOT BE LIABLE FOR INCIDENTAL CONSE QUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE OF THE PRODUCTS THE EXPRESS WARRANTIES IN THE PRECEDING SE...

Reviews: