![MIRKA Mirka ROS series Original Instructions Manual Download Page 12](http://html1.mh-extra.com/html/mirka/mirka-ros-series/mirka-ros-series_original-instructions-manual_1805984012.webp)
30
Product Configuration/Specifications: 12,000 rpm Random Orbital Sander
Specifications subject to change without prior notice.
*The values stated in the table are from laboratory testing in conformity with stated codes and standards and are not sufficient for risk evalu-
ation. Values measured in a particular work place may be higher than the declared values. The actual exposure values and amount of risk or
harm experienced to an individual is unique to each situation and depends upon the surrounding environment, the way in which the individual
works, the particular material being worked, work station design as well as upon the exposure time and the physical condition of the user. KWH
Mirka, Ltd. cannot be held responsible for the consequences of using declared values instead of actual exposure values for any individual risk
assessment.
Further occupational health and safety information can be obtained from the following websites:
https://osha.europa.eu/en (Europe)
http://www.osha.gov (USA)
Orbit
Pad Size
mm (in.)
Vacuum
Type
Model
Number
Product
Net Weight
kg (pound)
Heigh
mm (inch)
Length
mm (inch)
Power
watts (HP)
Air
Consumption
LPM (scfm)
*Noise
Level
dBA
*Vibration
Level
m/s
2
*Uncer-
tainty
K
m/s
2
2,5 mm
(3/32 in,)
77 mm
(3 in,)
Non-
Vacuum
ROS325NV
0,51 (1,12)
78,7
(3,10)
124,3
(4,90)
209 (0,28)
481 (17)
76,5
3,04
0,80
Central
Vacuum
ROS325CV
0,57 (1,26)
78,7
(3,10)
186,2
(7,30)
209 (0,28)
481(17)
74,5
3,20
0,81
Self-Gen
Vacuum
ROS325DB
0,59 (1,30)
78,7
(3,10)
190,1
(7,50)
209 (0,28)
481 (17)
84,5
2,66
0,76
5,0 mm
(3/16 in,)
77 mm
(3 in,)
Non-
Vacuum
ROS350NV
0,60 (1,33)
85,0
(3,35)
124,3
(4,90)
209 (0,28)
481 (17)
74,0
2,70
1,40
Central
Vacuum
ROS350CV
0,66 (1,47)
85,0
(3,35)
186,2
(7,30)
209 (0,28)
481(17)
76,0
2,30
1,20
Self-Gen
Vacuum
ROS350DB
0,68 (1,51)
85,0
(3,35)
190,1
(7,50)
209 (0,28)
481 (17)
88,0
2,80
1,40
The noise test is carried out in accordance with EN ISO 15744:2008 - Hand-held non-electric power tools -- Noise measurement code -- Engineering method
(grade 2) and EN ISO 11203:2009 Acoustics-Noise emitted by machinery and equipment-Determination of emission sound pressure levels at a work station and
other specified positions from the sound power level.
The vibration test is carried out in accordance with EN ISO 28927-3, Hand-held portable power tools – Test method for evaluation of vibration emission –
Part 3: Polishers and rotary , orbital and random orbital sanders.