Hilscher NT 50-RS-EN adapter cable pinout (female DSUB-9)
Description
PIN (colour)
GND
1 (white, WH)
Modbus RTU (A, RxD / TxD+)
4 (brown, BN)
Modbus RTU (B, RxD / TxD–)
5 (green, GN)
Shield
SHIELD
Modbus RTU
Modbus RTU over RS-485 is used to communicate with the motor drive. The motor drive is configured as a Modbus RTU
slave device and the default slave address is 86. The slave address can be changed if it conflicts with another Modbus
RTU slave device.
The J1 connector on the motor drive is used for Modbus RTU communication. A shielded twisted pair cable is recommended
and the shield should be earthed only at one point, normally at the master device. The A-pin of the J1 connector is
equivalent to RxD / TxD+ and the B-pin is equivalent to RxD / TxD–.
RS-485 configuration
19200
BAUD RATE
EVEN
PARITY
1
STOP BITS
8
DATA BITS
Coil registers (F1, F5, F15)
Desciption
Name
Data type
Address
Coils 1–11 are reserved for future
use.
Digital outputs
Uint16
00001 - 00012
Coil 12 is the relay located on the
motor drive.
Input registers (F4)
Description
Name
Data type
Adress
The number of times the speed
has dropped from set-point by
more than 25%.
Drop RPM count
Uint16
30001
The number of times the tool
temperature has exceeded the
“warm” limit, 79°C.
Warm tool count
Uint16
30002
The number of times the motor
drive temperature has exceeded
the “warm” limit, 73°C.
Warm motor drive count
Uint16
30003
The number of times the tool
temperature has exceeded the
“hot” limit, 134°C.
Hot tool count
Uint16
30004
The number of times the motor
drive temperature has exceeded
the “hot” limit, 117°C.
Hot motor drive count
Uint16
30005
The number of times the tool
temperature has exceeded the
“stop” limit, 142°C.
Stop tool count
Uint16
30006
The number of times the motor
drive temperature has exceeded
the “stop” limit, 123°C.
Stop motor drive count
Uint16
30007
9