background image

Mirka® Dust Extractor • 1230 L & 1242 L • 230 V • PC & AFC 

33

 CAUTION

Do not lift machine and case fastening accessory without ensuring that the storage case is safely installed . Note the 
weight and balance of the appliance in case of storage . Maximum weight of storage cases is 30 kg .

4.5  Recycling the machine

Make the old machine unusable .
1 .  Unplug the machine .
2 .  Cut the power cord .
3 .  Do not discard electrical appliances with regular household waste .

As specified in European Directive 2012/19/EU on old electrical and electronic appliances, used electrical 
goods must be collected separately and recycled ecologically .

5. Maintenance

5.1  Regular servicing and inspection

Regular servicing and inspection of your machine must be carried out by suitably qualified personnel in accordance 
with relevant legislation and regulations . In particular, electrical tests for earth continuity, insulation resistance, and 
condition of the flexible cord should be carried out frequently . 

In the event of any defect, the machine MUST be withdrawn from service, completely checked and repaired by an 
authorized service technician . At least once a year, a Mirka technician or an instructed person must perform a technical 
inspection including filters, air tightness and control mechanisms . 

5.2 Maintenance

Remove the plug from the socket before performing maintenance . Before using the machine make sure that the 
frequency and voltage shown on the rating plate correspond with the mains voltage . 

The machine is designed for continuous heavy work . Depending on the number of running hours – the dust filter 
should be renewed . Keep the machine clean with a dry cloth, and a small amount of spray polish .

During maintenance and cleaning, handle the machine in such a manner that there is no danger to maintenance staff 
or other persons . In the maintenance area:
•   Use filtered compulsory ventilation .
•   Wear protective clothing .
•   Clean the maintenance area so that no harmful substances get into the surroundings . 

During maintenance and repair work all contaminated parts that cannot be cleaned satisfactorily must be: 
•  Packed in well-sealed bags .
•  Disposed of in a manner that complies with valid regulations for such waste removal .

For details of after sales service, contact your dealer or Mirka service representative responsible for your country . See 
reverse of this document .

en

Summary of Contents for 1230 L PC

Page 1: ......

Page 2: ......

Page 3: ...zh 12 en Operating instructions 24...

Page 4: ...k reference guide is designed to help you when starting up operating and storing the unit The guide is subdivided into four sections which are represented by symbols Before starting DO READ OPERATING...

Page 5: ...Mirka Dust Extractor 1230 L 1242 L 230V PC AFC 5 A B 3 4 3x 2 Vibeke will make 3x 3 4 3x Vibeke will make 10 sec...

Page 6: ...6 Mirka Dust Extractor 1230 L 1242 L 230V PC AFC C...

Page 7: ...Mirka Dust Extractor 1230 L 1242 L 230V PC AFC 7 D Case fastening accessory x4 1 1 x4 2 2 3A 3B 4B 4B 3A 4A 4A 4A 4A...

Page 8: ...8 Mirka Dust Extractor 1230 L 1242 L 230V PC AFC E F 5 5 7 5 4 3 7 6 7 1 2 1 7 6 7 1 1 2 3 4 5 6 7 7...

Page 9: ...Mirka Dust Extractor 1230 L 1242 L 230V PC AFC 9 G H 4 1 4 2 3 4 4 5 4 6 7 4 5 6 1 2 4 5 6 3 4 5 6 4 5 6 7...

Page 10: ...10 Mirka Dust Extractor 1230 L 1242 L 230V PC AFC I 1 2 1 4 3 1 2 1 5 4 5 4 1 2 1 3 5 6 3 7 8 8 3 4 1 1 2...

Page 11: ...Mirka Dust Extractor 1230 L 1242 L 230V PC AFC 11...

Page 12: ...tractor 1230 L 1242 L 230V PC AFC zh 1 2 3 4 5 6 7 8 9 10 11 1 1 1 1 2 1 3 1 4 1 5 1 6 1 7 2 2 1 2 2 2 3 2 4 3 3 1 3 2 3 3 PC 3 4 AFC 3 5 3 6 3 7 3 8 4 4 1 4 2 4 3 4 4 4 5 5 5 1 5 2 6 6 1 6 2 A PC B A...

Page 13: ...Mirka Dust Extractor 1230 L 1242 L 230V PC AFC 13 zh 1 www mirka com Mirka 1 1 1 2 1 3...

Page 14: ...14 Mirka Dust Extractor 1230 L 1242 L 230V PC AFC zh L OEL 1 mg m3 L IEC 60335 2 69 OEL 1 mg m3 L 1 L 1 4 1 5 1 2 16 A 25 A 20 m 1 5 mm2 2 5 mm2 20 50 m 2 5 mm2 4 0 mm2 1 6 1 7...

Page 15: ...Mirka Dust Extractor 1230 L 1242 L 230V PC AFC 15 zh...

Page 16: ...16 Mirka Dust Extractor 1230 L 1242 L 230V PC AFC zh 2 2 1 Mirka...

Page 17: ...Mirka Dust Extractor 1230 L 1242 L 230V PC AFC 17 zh 2 2 2 3 Mirka Mirka 8999100411 5 pcs 8999100211 5 pcs 8999110311 8999110111 PET 8999110211 8999110411 230 V 8999101011 2 4 3...

Page 18: ...18 Mirka Dust Extractor 1230 L 1242 L 230V PC AFC zh 3 1 0 I I 0 I I I AFC 3 2 3 3 PC Push Clean 3 4 AFC AFC I 10 3 1...

Page 19: ...Mirka Dust Extractor 1230 L 1242 L 230V PC AFC 19 zh 3 5 3 6 PET 5 3 7 3 3 8...

Page 20: ...20 Mirka Dust Extractor 1230 L 1242 L 230V PC AFC zh 4 4 1 4 2 4 3 4 4 2 4 30 kg 4 5 1 2 3 2012 19 EU 5 5 1 Mirka...

Page 21: ...30 L 1242 L 2006 42 EC EMC 2014 30 EC RoHS 2011 65 EC EN 60335 1 2012 A11 2014 EN 60335 2 69 2012 EN 55014 1 2006 A1 2009 A2 2011 EN 55014 2 1997 A1 2001 A2 2008 EN 61000 3 2 2014 EN 61000 3 3 2013 EN...

Page 22: ...PX4 IPX4 IPX4 IPX4 I I I I l s 75 75 75 75 m3 h 270 270 270 270 CFM 159 159 159 159 kPa 25 25 25 25 hPa 250 250 250 250 inH20 100 100 100 100 LPA IEC 60335 2 69 dB A 68 2 68 2 68 2 68 2 dB A 60 2 60 2...

Page 23: ......

Page 24: ...onents 2 2 Hazardous dust 2 3 Spare parts and accessories 2 4 In explosive or inflammable atmosphere 3 Control Operation 3 1 Starting and operating the machine 3 2 Auto On Off socket outlet for power...

Page 25: ...by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge Children must be supervised to make sure that they do not play with the appliance...

Page 26: ...e connected via a residual current circuit breaker Arrange the electrical parts sockets plugs and couplings and lay down the extension lead so that the protection class is maintained Connectors and co...

Page 27: ...ep cord away from heated surfaces Keep hair loose clothing fingers and all parts of the body away from openings and moving parts Do not put any objects into openings or use with opening blocked Keep o...

Page 28: ...use the socket outlet on the machine for purposes specified in the instructions Outdooruseoftheappliancemustbelimitedtooccasionaluse 2 Risks 2 1 Electrical components DANGER The upper section of the m...

Page 29: ...xplosive corrosive liquids e g petrol solvents acids alkalis etc flammable explosive dust e g magnesium or aluminium dust etc 2 3 Spare parts and accessories CAUTION Spare parts and accessories The us...

Page 30: ...rn counter clockwise for speed control Turn to I Activate the dust extractor Turn to Stop the dust extractor Permanent power on socket Turn to I Activate Auto On Off operation Turn to I AFC Off Activa...

Page 31: ...d in the front part of the motor top and creates an earth ground connection to the inlet fitting of the container For correct operation the use of an electrically conductive or antistatic suction hose...

Page 32: ...rough the vacuum inlet Make sure that the rubber membrane passes the raised part of the vacuum inlet After emptying Close motor top on the container and secure the motor top with the container clamps...

Page 33: ...by an authorized service technician At least once a year a Mirka technician or an instructed person must perform a technical inspection including filters air tightness and control mechanisms 5 2 Maint...

Page 34: ...ractor Type 1230 L 1242 L Relevant EC directives Machinery Directive 2006 42 EC EMC Directive 2014 30 EC RoHS Directive 2011 65 EC Applied harmonized standards EN 60335 1 2012 A11 2014 EN 60335 2 69 2...

Page 35: ...5 2 5 Weight kg 16 16 16 16 lb 31 9 31 9 31 9 31 9 Filter surface area m2 0 5 0 5 0 5 0 5 Dust class L L L L Measured at container Specifications and details are subject to change without prior notic...