ASSEMBLING TX3-TOUCH-F15-B
AC or DC Door
Strikes:
see and
1
Auxiliary Door
Strike:
see
NO
NC
Jumper JW8
2
3
4
AC Door Strike or
Magnetic Lock
AC Power Supply
for Door Strike
AC Door Strike or Maglock
18 AWG
For a door strike: connect the
jumper wire to the top pin of
jumper JW8 (normally open).
For a maglock: connect the
jumper wire to the bottom
pin of jumper JW8 (normally
closed).
TS8
Jumper JW8
NO
NC
2
Door Strike
Note: Most door
strikes are non-
polarity.
Power Supply
Note: If AC power
supply is used,
polarity does not
apply.
Auxiliary Door
(Output 2)
18 AWG
TS9
+
-
+
-
4
Warning: Turn the power
off before wiring.
Install all power supplies outside the enclosure.
Wiring Requirements
Unless specifi ed otherwise, all wiring is a maximum
length of 1000 ft (304.8 m).
RS-485:
22 AWG twisted pair, maximum length: 4000
ft (1219.2 m). Mircom recommends shielded cable.
Door Strike:
The door strike power supply depends
on the door strike power requirements.
AC or DC Power
Supply for Door
Strike
DC Output
Door Strike or
Magnetic Lock
DC Door Strike
(Output 1)
18 AWG
TS8
TS9
3
The maximum supply for the AC or DC
Power Supply for Door Strike must not
exceed:
28 VAC / 1 A max
30 VDC / 1 A max
Trigger for door operator
Jumper JW8 controls
whether the contact
is normally open or
normally closed.
Alternative Wiring
for Dry Contact
TS8
Jumper JW8
NO
NC
Contact ratings for outputs 2-4:
125 VAC / 2 A
30 VDC / 1 A
DIP Switch Settings
for RS-485 Address
Address 1
ON
OFF
Address 4
Address 2
Address 3
1
8
1
8
1
8
1
8
5
Each Touch Screen must have a unique RS-485
address.
Use DIP switches 1-6 to set the RS-485 network
address. See LT-969 for details.
Camera Power
Supply (12 VDC)
Camera Supply
TS3
6
22”
(559 mm)
17 1/2”
(445 mm)
1 1/4”
(32 mm)
3 51/64”
(96 mm)
3 31/32”
(101 mm)
16 19⁄64”
(414 mm)
20 3/4”
(527 mm)
2 7/32”
(57 mm)
4 1/2”
(114 mm)
17 9⁄16”
(446 mm)
12 3/4”
(324 mm)
12 19⁄32”
(320 mm)
SW1
Mount the
Enclosure
1
The enclosure mounts on the wall. Mount the
enclosure right-side up (the Mircom logo on the
door is in the lower right corner).
You need:
4 fasteners appropriate for the wall that you are
mounting the enclosure on.
1. Find a suitable location for the enclosure. You can
mount the enclosure using the keyholes on the
back, or the knockouts on the side, or both.
2. Trace an opening in the wall for the enclosure
with one side aligned with a wall stud.
2. Cut an opening in the wall 3/32” (3 mm) larger
than the tracing, ensuring that one side is
aligned with the wall stud or supporting
structure.
3. Insert the enclosure into the wall cutout, and
using the side of the enclosure as a template
mark the hole mounting locations (either
keyholes or knockouts or both).
4. If you are using the keyholes, remove the
enclosure and place 2 fasteners halfway into the
wall into the two top keyhole locations.
5. Place the enclosure onto the top fasteners, then
lower it so that the fasteners fi t in the narrow
part of the keyholes.
6. Screw the other fasteners into the remaining
holes.
7. Tighten all fasteners into place.
Camera Supply:
see
6
DIP Switches:
see
5
Gauge
Distance
16
125 ft (38.1 m)
14
200 ft (60.96 m)
12
320 ft (97.536 m)
10
500 ft (152.4 m)
Maximum Power Supply Wire Distances