background image

LT-6613 Rev 1

Page 2 of 9

2.

Move the SW3 switch to the left.

Figure 2

SW3 on the left

3.

Connect the cables to the new board. Refer to the figures below.

4.

Turn on the lobby controller board.

5.

Turn on the Touch Screen.

You are done! If you need more help, call us at 1-888-660-4655.

Note:

Use the existing cables for the power connections to TS9 and for the button 
connections (SW-207), and use the cables included with this kit for all other 
connections.

Figure 3

Connections on MD-1236 for TX3-TOUCH-S15-B and TX3-TOUCH-F15-B

WX-081: CN1 on PC board

WX-079: CN31 on PC board

WX-109: TS2 on telephone 
access controller (not 
polarity sensitive)

WR-21160 and WR-21162:
Power (CN6)
on PC board

+

-

WX-110: TS4 (bottom)
on telephone access 
controller

WR-12223 and WR-12224: 
Left Speaker
WR-12223 and WR-12224: 
Right Speaker

WX-080: CN2 
on PC board

P3

P1

TS1

TS4A

TS12

P2

TS9

SW-207: Button

WR-21160 and 

WR-21162: Power 

terminals

TS11

SW3 on the LEFT

TS10A

TS4B

TS7

WX-520: CN4 
on PC board 
only if fan is 
present

TS6A

Fan (if present)

+

-

WX-070: 
Ground wire to 
chassis ground

WX-070: Ground 
wire to telephone 
access controller

-

+

+

-

-

+

Black (ground)

White (data)

Red (clock)

Yellow
Blue
Red

Red Black

Red Black

Red

Black

Yellow

Orange

Yellow

Orange

Red

Black

Red

Black

White

Green

Summary of Contents for RB-MD-1236

Page 1: ...your administrator password and then press OK 3 Select File Shut down Shut down 4 After the TX3 Configurator and Windows have shut down disconnect power from the Touch Screen 5 Turn off the lobby con...

Page 2: ...5 B WX 081 CN1 on PC board WX 079 CN31 on PC board WX 109 TS2 on telephone access controller not polarity sensitive WR 21160 and WR 21162 Power CN6 on PC board WX 110 TS4 bottom on telephone access co...

Page 3: ...to MD 1236 on TX3 TOUCH S15 B and TX3 TOUCH F15 B 4 TS11 on MD 1236 3 2 1 Button bottom view Notch Notch Button side view black white red green black 2 green 4 red 1 white 3 WX 110 TS1 on MD 1236 TS4...

Page 4: ...236 for TX3 TOUCH S15 B and TX3 TOUCH F15 B CN6 CN2 WX 081 P3 on MD 1236 CN1 WX 079 P1 on MD 1236 CN31 CN4 WX 080 P2 on MD 1236 WR 21160 and WR 21162 TS10A on MD 1236 WX 520 TS7 on MD 1236 only if fan...

Page 5: ...ave shut down disconnect power from the Touch Screen 5 Turn off the lobby controller board B Remove the old board Caution To prevent damage to the boards always hold them by the edges 1 Disconnect all...

Page 6: ...TS10B TS10A TS7 TS11 TS6A WX 079 CN31 on PC board WX 520 CN4 on PC board only if fan is present Black ground White data Red clock Fan if present WX 081 CN1 on PC board WX 070 Ground wire to chassis g...

Page 7: ...110 TS1 on MD 1236 TS4 WX 109 TS12 on MD 1236 not polarity sensitive TS2 TS2 Power switch WX 070 Ground wire to MD 1236 Black Red Black Red CN6 CN2 CN1 CN31 CN32 Touch Screen VGA cable CN14 CN4 WX 08...

Page 8: ...LT 6613 Rev 1 Page 8 of 9 Figure 13 Connections on the 22 inch display WX 082 USB extension on PC sub compact board CN32 on PC sub compact board MD 1256 TS10B on MD 1236...

Page 9: ...ller board B Remove the old board Caution To prevent damage to the boards always hold them by the edges 1 Disconnect the power harness from the current audio mixer board 2 Disconnect the ribbon cable...