LT-6613 Rev 1
Page 2 of 9
2.
Move the SW3 switch to the left.
Figure 2
SW3 on the left
3.
Connect the cables to the new board. Refer to the figures below.
4.
Turn on the lobby controller board.
5.
Turn on the Touch Screen.
You are done! If you need more help, call us at 1-888-660-4655.
Note:
Use the existing cables for the power connections to TS9 and for the button
connections (SW-207), and use the cables included with this kit for all other
connections.
Figure 3
Connections on MD-1236 for TX3-TOUCH-S15-B and TX3-TOUCH-F15-B
WX-081: CN1 on PC board
WX-079: CN31 on PC board
WX-109: TS2 on telephone
access controller (not
polarity sensitive)
WR-21160 and WR-21162:
Power (CN6)
on PC board
+
-
WX-110: TS4 (bottom)
on telephone access
controller
WR-12223 and WR-12224:
Left Speaker
WR-12223 and WR-12224:
Right Speaker
WX-080: CN2
on PC board
P3
P1
TS1
TS4A
TS12
P2
TS9
SW-207: Button
WR-21160 and
WR-21162: Power
terminals
TS11
SW3 on the LEFT
TS10A
TS4B
TS7
WX-520: CN4
on PC board
only if fan is
present
TS6A
Fan (if present)
+
-
WX-070:
Ground wire to
chassis ground
WX-070: Ground
wire to telephone
access controller
-
+
+
-
-
+
Black (ground)
White (data)
Red (clock)
Yellow
Blue
Red
Red Black
Red Black
Red
Black
Yellow
Orange
Yellow
Orange
Red
Black
Red
Black
White
Green