Installation Instructions

2

Installation Instructions

Controls and Displays

For precise definitions of control & display operation, refer to the manual of the fire alarm control panel that 

the annunciator will be connected to.

Notes:

 

• The RAM-216 is supplied with NP-386 paper labels for zone identification.
• This annunciator displays initiating circuit status only (no individual circuit troubles). 

Indicating and relay circuits are not remotely displayed. For more details, refer to the 
manual of the fire alarm control panel that the annunciator will be connected to.

• The RAM-216 has a keyswitch to enable the four slide-switch controls. The key 

should be appropriately secured.

Controls

Displays

System Reset, Signal Silence Switches

AC On, Common Trouble, Signal Silence LEDs

Buzzer Silence, Lamp Test Switches

16 circuit status bi-coloured (red/amber) LEDs

Standard Electrical
Box

Clear Lexan

Flush Mount

Secure
with
#6-32
Screws

Paper Labels

Wall

Std
Elec.
Box

Std
Elec.
Box

Wall

Surface Mount

Summary of Contents for RAM-216

Page 1: ...Remote Multiplex Annunciator Panel LT 658 Rev 6 April 2007 Wiring Installation Manual Advanced Life Safety Solutions BUZZER SILENCE A C ON SIGNAL SILENCED COMMON TROUBLE SIGNAL SILENCE LAMP TEST SYSTE...

Page 2: ...ctions 3 DIP Switch Settings 4 Jumper Selection 4 Specifications and Features 5 Enclosure 5 Electrical Specifications 5 Current Drain for Battery Calculations 5 Warranty and Warning Information 6 Warn...

Page 3: ...ontrol access is by a keyswitch Each circuit indicator is a bi colour LED that is automatically configured to match the fire alarm control panel configuration Technical Support For all technical suppo...

Page 4: ...s Indicating and relay circuits are not remotely displayed For more details refer to the manual of the fire alarm control panel that the annunciator will be connected to The RAM 216 has a keyswitch to...

Page 5: ...current for all annunciators summed together Note All circuits are power limited and must use type FPL FPLR or FPLP power limited cable WARNING Accidentally connecting any of the 24 VDC wires to the R...

Page 6: ...used for FA 204 FA 204E FA 1000 FA 300 and FR 320 Move jumper JP1 to pins 1 and 2 to provide a 16 bit checksum used with the FX 2000 version 2 X X or higher and the FX 350 JW4 Jumper Intact Buzzer si...

Page 7: ...o 16 points Not expandable Standby 35 mA Max All LED s illuminated 140 mA max Current Drain for Battery Calculations The lamp test feature draws the maximum normal current because it illuminates all l...

Page 8: ...any length are often accompanied by voltage fluctuations which may damage electronic equipment such as a fire alarm system After a power interruption has occurred immediately conduct a complete system...

Page 9: ...Audible notification appliances however loud may not be heard by a hearing impaired person Telephone Lines If telephone lines are used to transmit alarms they may be out of service or busy for certai...

Page 10: ...o provide a suitable installation environment for the products damage caused by use of the products for purposes other than those for which it was designed damage from improper maintenance damage aris...

Page 11: ...price of the replacement product will be charged for each replacement unit WARNING Mircom Technologies Ltd recommends that the entire system be completely tested on a regular basis However despite fr...

Page 12: ...Tel 905 660 4655 Fax 905 660 4113 Mircom 2006 Printed in Canada Subject to change without prior notice www mircom com Advanced Life Safety Solutions U S A 60 Industrial Parkway PMB 278 Cheektowaga NY...

Reviews: