Align and attach the MD-1244 to the Touch Screen door using a multimeter probe:

1.  Expose the adhesive on the double-sided tape that is attached to the flat side of the 

MD-1244 board.

2.  Open the door.

3.  From the front of the door, insert the multimeter probe through the door’s microphone 

opening.

4.  Carefully insert the tip of the multimeter probe into the microphone opening on the MD-

1244.

The microphone on the other side of the opening is very delicate. Permanent damage to 
the microphone can result if you force the tip of the multimeter probe too far into the 
microphone opening.

5.  Align the MD-1244 so that the terminal for the wiring harness is on the bottom (see 

Figure 3).

Figure 3    Proper alignment of the of the MD-1244 board

6.  Using the multimeter probe as a guide, move the MD-1244 towards the door until the 

MD-1244 attaches to the door.

Figure 4    Aligning the MD-1244 with the microphone hole

7.  Go to the section 

D. Connect the wiring harness

 below.

Terminal for the 
wiring harness

Summary of Contents for MD-1244

Page 1: ...hut down the unit and disconnect power B Remove the old microphone C Attach MD 1244 to the door D Connect the wiring harness Details on how to perform these steps are in the following pages A Shut down the unit and disconnect power It is essential that you follow the proper shut down procedure To shut down the TX3 Touch Screen 1 At the Touch Screen terminal enter 9999 2 Enter your administrator pa...

Page 2: ...the Touch Screen door 4 Disconnect the old microphone cable C Attach MD 1244 to the door The MD 1244 attaches to the inside of the Touch Screen door with double sided tape The microphone fits into an indentation in the door For ideal sound quality the microphone opening on the flat side of the MD 1244 see Figure 2 must align with the microphone opening on the door Figure 2 Location of the micropho...

Page 3: ...e MD 1244 The microphone on the other side of the opening is very delicate Permanent damage to the microphone can result if you force the tip of the multimeter probe too far into the microphone opening 5 Align the MD 1244 so that the terminal for the wiring harness is on the bottom see Figure 3 Figure 3 Proper alignment of the of the MD 1244 board 6 Using the multimeter probe as a guide move the M...

Page 4: ...pin connector on the wiring harness to the 4 pin terminal on the lobby controller board as shown in Figure 5 2 If there is a jumper on JW11 remove it see Figure 5 3 Reconnect power to the unit and then turn it on Figure 5 Microphone wiring on MD 1245 Speaker Connection White Microphone Connection Red Black Unused Unused JW11 open Sheild ...

Reviews: