Installation Instructions for Replacement 
MD-1243 and MD-1244 Microphone

This document applies to four kits:

RPL-MD-1243

 and 

RPL-MD-1244

: for non-Touch Screen models ending in -C, for 

example TX3-1000-8U-C

RPL-MD-1243-TOUCH

 and 

RPL-MD-1244-TOUCH

: for Touch Screen models ending in 

-C, for example TX3-TOUCH-F15-C

The microphones 

MD-1243

 and 

MD-1244

 are identical in terms of installation and wiring.

Each kit consists of the following parts:

replacement microphone circuit board with adhesive strips on flat side

wiring harness and terminal block

You will also need the following tools:

Screwdriver or a utility knife

A multimeter probe

To install the microphone, you must perform the following steps:

A. Shut down the unit and disconnect power

B. Remove the old microphone

C. Attach the new microphone to the door

D. Connect the wiring harness to the lobby controller board

Details on how to perform these steps are in the following pages.

A.

Shut down the unit and disconnect power

If you are installing the replacement microphone on TX3 Touch Screen, it is essential that you 
follow the proper shut down procedure.

Shut down the TX3 Touch Screen

1.  At the Touch Screen terminal, enter 9999.

2.  Enter your administrator password, and then press 

OK

.

3. Select 

File > Shut down > Shut down

.

4.  After the TX3 Configurator and Windows have finished shutting down, disconnect power 

from the Touch Screen.

Summary of Contents for MD-1243

Page 1: ...he following tools Screwdriver or a utility knife A multimeter probe To install the microphone you must perform the following steps A Shut down the unit and disconnect power B Remove the old microphone C Attach the new microphone to the door D Connect the wiring harness to the lobby controller board Details on how to perform these steps are in the following pages A Shut down the unit and disconnec...

Page 2: ...or The new microphone attaches to the inside of the door with double sided tape The microphone fits into an indentation in the door For ideal sound quality the opening on the flat side of the new microphone see Figure 3 must align with the microphone opening on the door Align and attach the new microphone to the door using a multimeter probe 1 Remove the sticker to expose the adhesive on the flat ...

Page 3: ...de of the opening is very delicate Permanent damage to the microphone can result if you force the tip of the multimeter probe too far into the microphone opening 5 Align the microphone so that the terminal for the wiring harness is on the bottom see Figure 4 Figure 4 Proper alignment of the of the microphone board 6 Using the multimeter probe as a guide move the microphone towards the door until t...

Page 4: ...in connector on the wiring harness to the 4 pin terminal on the lobby controller board as shown in Figure 6 2 If there is a jumper on JW11 remove it see Figure 6 3 Reconnect power to the unit and then turn it on Figure 6 Microphone wiring Speaker Connection White Microphone Connection Red Black Unused Unused JW11 open Sheild ...

Reviews: