Replacing Appliance Components
46
2
Cable Routing
Cables that extend through the appliance front-to-back are routed along a cable
path within the interior right wall of the appliance chassis. The cables are secured
by a cable retention bracket that attaches to the inner wall.
Removing the Cable Retention Bracket
To remove the cable retention bracket:
1.
Remove the cooling shroud. See
2.
Remove the cooling fan bracket. See
3.
Press outward on the blue release latch on the cable retention bracket and slide
the bracket back until the tabs at the bottom of the bracket clear the chassis
(
).
4.
Lift the cable retention bracket off the chassis wall.
Figure 22 Removing and Installing the Cable Retention Bracket
Installing the Cable Retention Bracket
To install the cable retention bracket:
1.
Insert the hooks and tabs of the cable retention bracket into the slots in the
chassis wall and slide the bracket back until the latch engages.
2.
Install the cooling fan bracket. See
3.
Install the cooling shroud. See
1
cable retention bracket
2
release latch
3
hooks (3)
4
right chassis wall
5
chassis slots (6)
6
tab (3)
2
4
1
6
5
3