Guide to installation & Operation
UAP-711i/712i
x
15
3.2.2 Configuration
Switch
Channel 1
Switch
Channel 2
Position
Designation
A75
Rear panel selection (75 or 110
Ω
)
SW51
SW61
SW71
SW81
SW91
SW53
SW63
SW73
SW83
A110
A75
SW4
A110
Rear panel selection (75 or 110
Ω
)
{REF.IN passive loop respectively (OFF or ON)}
LOZ
75
Ω
termination associated to “REF.IN” input
LD75
HIZ
LOZ
110
Ω
termination associated to AES3 reference input
LD110
HIZ
Analog RMS value associated to 0DBFS
dBu
+15
+16
+18
+20
+21
+22
+24
+24
SW1
ON
OFF ON
OFF ON
OFF ON
OFF
SW2
ON
ON
OFF OFF ON
ON
OFF OFF
SW1, SW2, SW3
SW3
ON
ON
ON
ON
OFF OFF OFF OFF
ON
600
Ω
input impedance Analog left input
IN1L
IN2L
OFF
12 k
Ω
input impedance Analog left input
ON
600
Ω
input impedance Analog right input
IN1R
IN2R
OFF
12 k
Ω
input impedance Analog right input
J9
Spares jumpers