SDM-771P
/75/110
4
3 Installation
3.1 Power Supply
The power supplies LKS-WSA and LKS-WSE, for 110V and 220V
operation respectively, are used to power the SDM-771p/75/110.
Each power supply provides a reg5VDC@750mA power
source. Plug the power supply into a wall or power bar outlet.
The SDM-771p uses a mini XLR-3 connector for its power needs;
figure 3.1 provides a detailed pinout of the male connector.
Figure 3.1
Power connector pinout
3.2 AES Input
SDM-771p/75:
BNC socket: Connect an asymmetric AES 75
Ω
signal to an
AES
IN
BNC connector. This signal must comply with the AES3-id or
SPDif standard.
SDM-771p/110:
Three-point female XLR connector: Connect a symmetric AES-
110
Ω
signal to an
AES IN
connector (refer to figure 3.2 for con-
nector pinout). This signal must comply with the AES3 standard
(professional or consumer).
+5VDC
GND
Shield