3. Installation
Making Alarm Connections
To create an indicator box, connect to the ‘ALARM’ connection using a DE9 female connector,
wiring as shown in Figure 3-19. Each pin monitors a specific function and activates a specific
alarm.
Figure 3-19. Alarm Connections and On/Off Switches
The following lists each DE9 pin and the associated alarm. The pin number listed corresponds to
the pin numbers in Figure 3-19:
Typical Circuit 1
Customer-supplied relay
contacts NC, (but open during
alarm condition)
External Power,
30VDC max, 150mA max
Normally ON, the LEDs turn off to indicate failure
1
COM
Normally OFF, the LEDs turn on to indicate failure
30VDC max, 150mA max
External Power
1
1
2
3
4
5
6
7
8
9
1
2
3
4
5
Alarm COM
Alarm 1
Alarm 2
Alarm 3
Alarm 4
8
7
8
9
Alarm 5
Alarm 6
Alarm 7
Alarm COM
Typical Circuit 2
COM
Pin
Signal
Description
Possible Conditions Causing the Alarm
1, 9
Alarm_COM
Common
Common connection for all alarm pins.
2
Alarm_1
Major Alarm
Indicates missing reference inputs, or missing power
supplies.
3
Alarm_2
Minor Alarm
Alarm_3, or Alarm_4, or Alarm_5, or Alarm_6
4
Alarm_3
Power Supply
Missing power supply module.
5
Alarm_4
Video Ref
Missing Video Ref 1 or Video Ref 2.
6
Alarm_5
AES3 ref
Not used in NV8256-Plus.
7
Alarm_6
Fans or temperature
Indicates a fan failure or module over temperature.
8
Alarm_7
Control module health
Any control module not “healthy.”
Summary of Contents for NV8256-Plus
Page 10: ...x Rev 1 3 29 Mar 09 Table of Contents ...
Page 60: ...50 Rev 1 3 29 Mar 09 3 Installation Verification ...
Page 66: ...56 Rev 1 3 29 Mar 09 5 Configuration UniConfig ...
Page 72: ...62 Rev 1 3 29 Mar 09 6 Maintenance Obtaining Service ...
Page 82: ...72 Rev 1 3 29 Mar 09 9 Part Numbers Frame Expansion ...
Page 88: ...78 Rev 1 3 29 Mar 09 Index ...