GUIDE TO INSTALLATION AND OPERATION
4
| ENC-291p
4.0 Operation
4.1 Switch Settings
Figure 4 shows the location of the slide switches and the status
LED.
Output setup and format (SW1)
Normal, Y only and Test (SW2)
picoLink
COMPOSITE
OUT
SDI IN
Status LED
7.5
IRE
0 IRE
Al
t.
O
u
t
Nor
m
a
l
Y O
n
ly
Te
st
ENC-291p
Miranda Technologies inc.
Made in Canada
Figure 4: ENC-291p slide switch and LED locations
Output setup and format switch (SW1)
7.5 IRE:
To add a 7.5 IRE setup to the output NTSC
composite signal, set SW1 to this position. There is
no setup for PAL, PAL-M, and PAL-N output signals.
0 IRE:
For no setup on the output composite signal, set
SW1 to this position.
Alt. Out:
To enable PAL-M and PAL-N outputs during 525-
line and 625-line input formats respectively, set SW1
to this position. Refer to Table 1 for the output
format provided during this setting.