GUIDE TO INSTALLATION AND OPERATION
DV |
3
-
Remote-control using IEEE-1394 (e.g. a DV VTR) or through the
RS-422 serial port (compatible with basic commands of the Sony
BVW-75 protocol)
2 Installation
2.1 Connections
Refer to figure 2.1 and to the following description when connecting the
DV-.
Figure 2.1
Rear view of the DV-
1 DV In/Out
Connect a DV source to one of the DV connectors at the rear of the DV-
for input and output. Source must comply with IEEE-1394
(i.Link) standard. The 4-pin and 6-pin connectors effectively provide
active loop-through when the unit is turned on.
2 SDI In/Out
Connect an SDI signal to the SDI input BNC connector (left-hand side)
labeled SDI. The DV- accepts 4:2:2 serial digital video signals
in either 525 or 625 line formats. The input signal must conform to the
SMPTE 259M standard. For DVITC timecode support, insert a
timecode conforming to SMPTE 12M in the input signal. Connect
destination equipment to the SDI output BNC connector (right-hand
side). The DVITC timecode in the output signal respects the same
standard as the one in the input signal.
3 AES In/Out
Connect an unbalanced AES signal to the AES input BNC connector
labeled AES. The DV- supports 32, 44.1 and 48 kHz sample
rates. This signal must comply with the AES-3id-1995 (SMPTE 276M)
standard. Connect destination equipment to the AES output BNC
connector (right-hand side).
4 LTC In/Out
Connect an LTC signal to the LTC input BNC connector labeled
LTC
(upper one). The DV- accepts LTC signals for 525 or 625 line