GUIDE TO INSTALLATION AND OPERATION
DEC-291p |
3
3.0 Installation
3.1 Power Supply
The LKS-WSU power supply is used to power the DEC-291p for
both 110V and 220V operation. This power supply provides a
reg5 VDC@1A power source over an input range of 90 –
260 VAC. The DEC-291p employs a mini XLR-3 connector for its
power needs. Figure 3 shows a detailed pinout of the male
connector.
1 3
2
(male connector-facing)
Pin 1: Shield
Pin 2: GND
Pin 3: +5 VDC
Figure 3: Power connector pinout
3.2 Composite Input
Connect an NTSC, PAL, PAL-M, PAL-N or SECAM composite
signal conforming to the SMPTE 170M or ITU-R BT.470-6
standard respectively to the BNC labeled COMPOSITE IN.
3.3 SDI Output
The SDI serial digital output signal is available at the BNC
labeled SDI OUT. The output signal conforms to the SMPTE
259M-C standard.
Summary of Contents for dec-291p