Miranda DDA-1112 Manual To Installation And Operation Download Page 5

DDA-1112   Digital Audio Distribution Amplifier 

Guide to Installation and Operation 

 

Config Tab 

No Signal Delay sub-tab 

This tab sets the card’s behavior in the event of a loss or absence of audio 
signal content. 

A signal absence is declared when the signal level is lower than the signal 
threshold during the selected period.  

The threshold can be set through the pull-down box to –72, -66, -60, -54 or -
48 dBFS, the default value is –60 dBFS.  

The signal absence period can be adjusted from 0 to 255 seconds. The 
default value is set to 15 s, an input box is available to enter a numerical value 
directly. 

Cable Correction sub-tab 

Mode MANUAL 

This mode allows a manual adjustment of the correction applied to the input 
signal. Look at the input status icon to facilitate the setting. An input box is 
available to enter a numerical value directly. 

Mode AUTO 

A START will initiate an automatic sequence, indicated by PROCESS. When 
the input status becomes correct it will stop and SUCCESS will be displayed. 
FAIL will be displayed to indicate that no correction has been found that will 
yield a correct input status 

Load Factory 

The Factory profile is a read-only set of factory-selected values that can be 
used to return your DDA-1112 to a standard operating condition. 

See the DDA-1112 Menu, page 3, to see the default values for all parameters. 

 

 

Alarms Tab 

Selecting the Alarm config button opens a separate window 
for error status reporting. The alarm Configuration Panel 
shows all measured parameters and offers the following 
options for each: 

Choose an alarm Name, use the pull-down box in the 
Overall alarm column to select the level associated to this 
alarm: Disabled, Mino, Major or Critical. 

Check Log events to enable logging. The result is stored in a 
database managed with GSM n iControl Navigator. 

In the bottom of the column Status/Name, the Card LED  
color follows the status of the physical card LED, as defined 
in the front panel menu Configure Alarm (page 4).  

The overall Status is reflected by the color of the indicator 
attached to the card in iControl Navigator. It is also 
displayed in the upper left corner of the iControl Interface of 
the DDA-1112. 

GSM is a dynamic register of all the system alarms, it is also 
an alarm provider for external applications

 

 

DDA-1112 

Page 5 of 6 