ADA-1023   Single/Dual Analog Audio Distribution Amplifier

 

Guide to Installation and Operation

 

 

 

ADA-1023 

Page 3 of 4 

Operating Parameter Adjustment 

The ADA-1023 has operating parameters which may be adjusted 
at the controller card interface. After pressing the SELECT 
button on the ADA-1023 card, use the keys on the local control 

panel (described in the Controller card manual) to step through 
the displayed menu and adjust the parameters. The menus are 
shown below.  
 

 

 
 

NO SIGNAL DELAY

CONFIGURE ALARM

STATUS

VERSION

OVERLOAD 1

ALARM LEVEL

ALARM REPORT

NO SIGNAL 1

ALARM REPORT

ALARM LEVEL

NONE

, GPI

NONE

, GPI

GREEN, 

YELLOW

, RED, FLASH RED

GREEN, YELLOW, 

RED

, FLASH RED

0, ..., 

15

, ..., 255 [sec]

REAR PANEL ERROR, OVERLOAD 1, OVERLOAD 2, OVERLOAD 1&2,

NO SIGNAL 1, NO SIGNAL 2, NO SIGNAL 1&2, ALL OK

OVERLOAD 2

ALARM REPORT

ALARM LEVEL

NONE

, GPI

GREEN, YELLOW, 

RED

, FLASH RED

NO SIGNAL 2

ALARM REPORT

ALARM LEVEL

GREEN, 

YELLOW

, RED, FLASH RED

NONE

, GPI

SIGNAL THRESHOLD

-48, -42, -

36

, -30, -24  [dBu]

OVERLOAD THRESHOLD

-9, ..., 

+24

   [dBu]

SINGLE, DUAL

UC Vxxx

MONITORING

OUT 1

, OUT 2, OUT 1&2

FACTORY DEFAULT

RESTORE

 

 
 
 
 
 
 
 

OPERATION (continued) 

STATUS menu 

 

Displays status of the different board alarms. The higher-level 
alarm is displayed, even if not configured to activate the 
STATUS LED. 

ALL OK 

indicates an absence of alarms. 

REAR PANEL ERROR

 

Absence of the rear panel or an 

incompatibility between the module and the rear panel. The 
STATUS led turns on flashing red  

OVERLOAD

     

Indicates an internal signal level higher than 

the overload threshold (channel indicated 1, 2, 1&2).

 

NO SIGNAL    

Indicates an internal signal level lower than the 

signal threshold during a user defined period (channel 
indicated 1, 2, 1&2).

 

 
 

NO SIGNAL DELAY menu 

Signal absence is declared when the level signal is lower than 
the signal threshold during the selected period, which can be 
adjusted from 0 to 255 s. The default value is set to 15 s. 

SIGNAL THRESHOLD menu 

The presence signal threshold can be adjusted from -48 to -24 
dBu by 6 dBu steps. The default value is -36 dBu S. 

OVERLOAD THRESHOLD menu  

The overload signal threshold

 

can be set from –9 to +24 

dBu. The default value is +24 dBu.

 

MONITORING menu 

Allows the pre-selection of the monitored signal. The 
ON/OFF command will come from a monitor module like 
the MSB-1121 in slot 20 of the Densité frame.

 

 
 