11
Warning!
Do not ix the shower unit to the wall until plumbing and electrical
installations have been completed.
1.
Decide on a suitable location for
the shower unit
avoiding buried
cables and pipes
. The unit should be
positioned at a height convenient for
all the family (at least 200 mm below
the ceiling to allow for the itting and
removal of the unit cover).
The handset should spray away from
the shower unit, either down the
centre line of the bath or across the
shower cubicle opening. Make sure
when the hose retaining ring is placed
on the lowest position on the slide bar,
the handset does not fall below the
minimum clearance gap
, between
the bath or shower tray spillover level
of 25 mm.
2.
Hot and cold inlet supply connections
are:
Hot – Left
Cold – Right
Run the hot and cold water supply
pipes at 28 mm centres, make sure
that the pipe ends project 30 mm into
the inlet manifold.
Warning!
Supply connections
must
not
be connected in reverse.
Caution! Do not
use stainless steel
piping for inlet pipework.
Caution!
If the pipework is chrome
plated remove all traces of chrome
from the connecting surfaces. If the
chrome is not removed then the
inlet manifold collets will
not
grip the
supply pipe.
25 mm Minimum
Spillover level
Hose Retaining Ring
All dimensions in millimetres
Miniature Trunking
275
28
30
30
H
C