10
35 mm
Allow a minimum of
150 mm either side
of mixer to wall
2.
Use the installation template to mark the
positions of the holes for the backplate and
the pipe centres.
For rising or falling supplies the pipe
positions should be set 35 mm from the
centre of pipe to the finished wall at 153
mm centres.
Note!
Allow a minimum of 150 mm either
side of the mixer to allow servicing of the
hot and cold inlet filters.
Note!
The thermostatic mixer has
adjustable inlets to fit existing pipework
centres between 139 mm and 153 mm.
6 mm Drill
Wall Plug
10 mm
minimum
between elbow
and finished
wall surface
Ø32 mm
13 mm from finished wall
surface
Elbow
Recess Ø32 mm
x 10 mm deep
13 mm
153 mm
HOT
COLD
Screw
Backplate
3.
For solid walls drill the holes for the
backplate with a 6 mm drill and insert the
wall plugs. For other types of wall structure
alternative fixings may be required (not
supplied).
4. For Rear Entry Supplies Only:
a)
Drill the holes for the supply pipes at
153 mm centres.
b)
Recess the inlet holes Ø32 mm x 10 mm
deep to allow for the concealing plates.
Note!
Depth must be sufficient to
prevent the concealing plates fouling
on the plumbing elbows.
5.
Fit the supply pipework:
Hot - Left, Cold
- Right.
The inlet pipework should extend
13 mm from the finished wall surface.
Note!
If it is not possible to install the mixer
with this pipework configuration complete
the installation then refer to section:
‘Reversed Inlet Supplies’
.
6.
Remove the backplate from the mixer by
loosening the grubscrew with a 2.5 mm
hexagonal key.
7.
Secure the backplate to the wall using the
screws.
Summary of Contents for Select Flex HP-S