background image

Digital BodyFat Scale - SBF525

15

Specifications 

of Scale

• 

Capacity: 

180kg / 397lb / 28st: 5lb

• 

Division:

 0.1kg / 0.2lb

• 

Weight unit: 

kg / lb / st: lb

• 

Minimal weight:

 5kg

• 

Function key: 

 

 , SET,  

, UNIT

• 

Display:

 Blue LCD with white 

backlight

• 

Battery: 

3xAAA

• 

Number of user profiles:

 8

• 

Age range:

 10~100

• 

Height:

 80~220cm /2ft 7.5inch~7ft 

2.5inch

• Athlete measuring mode for people 

over 18 years

• 

User identification: 

Identifies user 

automatically according to the last 
measured weight

• %Body fat, %Total Body Water, 

% Muscle Mass, % Bone Mass 

measuring functions

• Weight indicator
• Auto on or press UNIT or touch 

SET to switch on

• Auto off function

Summary of Contents for SBF525

Page 1: ...User Guide www mirabrands com MIRA Digital BodyFat Scale SBF525 ...

Page 2: ... Introduction 04 About the MIRA digital body fat scale 05 Before your first use 06 First time use 12 Tips for increasing accuracy 13 Trouble shooting 15 Specifications of scale 16 Warranty information Index ...

Page 3: ...itor your body fat body water muscle mass and bone mass Your MIRA Scale comes with the following MIRA Digital Body Fat Scale User Manual 3 AAA batteries 2 Year MIRA Guarantee Please read this manual before use If you have any questions regarding the operation of your MIRA Digital Body Fat Scale please call us at 925 460 0900 from 9 00 AM to 5 00 PM Monday through Friday Pacific Standard Time ...

Page 4: ...sistance the signal encounters This signal is perfectly safe and you will not feel it The scale displays your weight body fat per centage total body water percentage muscle mass percentage and bone mass You can use this scale for up to 8 different users WARNING This scale is not recommended for people that use devices like the pacemaker or any other implanted medical devices metal plates screws or...

Page 5: ...actors like eating drinking exercise wet feet menstruation medications may cause fluctuations in weight and other measurements Keep this is mind when tracking trends Before your first use 1 Turn the scale upside down and locate the battery compartment 2 Install the batteries 3 AAA making sure the and are aligned correctly 3 Close the battery door turn the scale correct side up and wait until 00 is...

Page 6: ... light comes on Step off the scale The scale is now calibrated To check your weight stand on the scale both feet evenly on each side and stand still After a few seconds you will see the weight Please recalibrate when you change batteries or move the scale to a dif ferent location Symbol Description male female athlete underfat healthy overfat obese LCD Display ...

Page 7: ...on or touch SET in weighing mode when you are weighing yourself The user No P1 P8 will flash Touch or to select the desired user number and then touch SET to confirm to enter set up mode Touch or to select gen der or athlete mode and then touch SET to confirm There are four pos sibilities male male athlete female female athlete Athlete is defined as a person who exercises more than 10 hours per we...

Page 8: ...art measuring after is shown on the LCD ac cording to the measuring procedure below Note If you do not press any keys in setup mode for 20 seconds the scale will turn back to weighing mode Measuring Weight manually select user Please put the scale on a flat sur face Touch SET to switch on and use or to select your user number P1 P8 Please wait until the LCD displays 0 0 ...

Page 9: ...e will start measuring other values The display will show an o moving from left to right Once the scale is done with the meas urements the results will be shown in cycles for three times and then the scale will turn off automatically Measuring automatic user identification Note Before using automatic user identification measuring method ...

Page 10: ...er values will start automatically with the o mov ing from left to right If there is only one user whose last weight data is close to the current one it will be selected automatically The results will be shown in cycles for three times and then the scale turn off If there are more than one users whose last weight data is close to the current one they would be shown on the display For example of us...

Page 11: ...how Please use or to select the correct user number Touch to select P1 and for P2 Note If you do not make a selec tion the scale will turn off after about 40seconds Once you select the user number the results will be shown in cycles for three times and then the scale will turn off ...

Page 12: ...same time of day for each time Make sure you stand with bare feet for accurate measurement Ensure that your feet are dry and not sweaty before you weigh yourself Please be sure your feet are not wet so as to not slip on the glass This scale is more of a trend indicator of body fat percentage rather than an exact number If the scale will not be used for a long period please remove bat teries Clean ...

Page 13: ...turn off after a few sec onds Please change the batteries Overload indicator Solution Please remove the weight on the scale to protect the load cells Measuring error indicator Only the weight data is shown the weight does not lock in Addition ally the scale turns off after a few seconds Weight data is shown the weight does not lock in Additionally the scale turns off after a few seconds ...

Page 14: ...r and scale turns off after a few seconds weight data is shown the profile number does not appear and scale turns off after a few seconds Please stand still and select your profile and make sure you are standing with bare feet WARNING The measurements provided are not substitutes for physician as sessments Always consult your physician to determine appropri ate goals for your body ...

Page 15: ...ite backlight Battery 3xAAA Number of user profiles 8 Age range 10 100 Height 80 220cm 2ft 7 5inch 7ft 2 5inch Athlete measuring mode for people over 18 years User identification Identifies user automatically according to the last measured weight Body fat Total Body Water Muscle Mass Bone Mass measuring functions Weight indicator Auto on or press UNIT or touch SET to switch on Auto off function ...

Page 16: ...ging of Unit and the cost of shipment to MIRA s designated loca tion You must return Unit within ten 10 business days after issuance of the RGA number together with i a copy of your receipt bill of sale or other proof of original purchase ii a written descrip tion of the alleged defect and iii your address and telephone number MIRA does not accept responsibility for any Unit lost in transit and re...

Reviews: