![Mira REALM Installation, Operation, Maintenance Manual Download Page 6](http://html1.mh-extra.com/html/mira/realm/realm_installation-operation-maintenance-manual_1804969006.webp)
6
4
Section
Specifications
1. Pressure range
1.1.
Minimum operating pressure (Gas Water Heater)
1.0 bar
.
1.2.
Minimum operating pressure (Gravity Feed)
0.1 bar
.
1.3.
Maximum maintained pressure
3.0 bar
.
1.4.
Maximum static pressure
10.0 bar
.
1.5.
Maximum pressure loss ratio
5:1
.
2. Temperature control
2.1.
Single sequential lever allows the temperature selected to range from the cold
water supply temperature through to a pre-set maximum.
2.2.
The maximum blend temperature is factory set at
42 °C
. This can be reset
according to site requirements.
2.3.
Accurate maximum blend temperatures can be set using typical inlet supply
temperatures:- Cold
10 - 15 °C
, Hot
60 - 65 °C
.
2.4.
The inlet water temperature should be at least
10 °C
above the required blend
temperature to ensure correct shower performance.
2.5
Maximum hot water inlet supply temperature
82 °C
.
Note!
The shower control can accept temporary temperature excursions above
82°C
without damage, however operation at such elevated supply temperatures is
not recommended. For reasons of general safety, hot water storage temperatures
should ideally be maintained at between
60-65°C
where serving ablutionary applica-
tions.
3.Plumbing Connections
The shower control connections are all 15mm compression (nuts and olives are
provided).
Hot and Cold inlets are clearly marked for the shower control and
must
be con-
nected as described in the
Installation
section.