5. Donotfitanyformofflowcontrolintheoutletpipeworkiftheshowerfittingsare
installedinconjunctionwithaproductthatrequiresthefittingstoactasavent(e.g.
anelectricshower).
6.
Donotuseexcessiveforcewhenmakingconnections.
7.
Special consideration should be given to the fixing arrangements when installing
onto a dry lined, stud partition, shower cubicle or laminated panel wall structures.
Installers may wish to obtain alternative proprietary cavity fixings, or choose
other options, however, these methods of fixing are beyond the scope of this
guide.
Note!
An alternative Slide Bar Support Pack is available. Contact our Customer
Services team for more details.
Installation of the Slide Bar
1.
Werecommendthattheslidebarisinstalledwiththeendsflush.Markthewallfixing
positionsanddrilltwoholestosuitthewallfixings.
Caution!
Do not
drillintohiddencablesorpipesinthewall.
Note!
Foranewinstallationoptimumfixingcentresare635 mm.Replacementinstallation
fixingcentresare635 mmmaximum.
2.
Fitthewallplugsandthemountingbracketsandsecurewiththewallscrews.
Note!
Checkforverticalalignmentbeforetightening.Themountingbracketsareslotted
toaidthisalignment.Thenfullytighten.
3.
Fittheclampbracket(rotatethelevertohelpwiththeinstallation),thehoseretaining
ring(ifapplicable)andtheslidebarsupportstotheslidebar.
4.
Makesurethatthewallscrewsareflushwiththeinsideedgeofthemountingbrackets.
Fittheslidebarsupportsoverthemountingbrackets,thenadjusttheslidebarvertically
ensuringanequallengthofslidebarprotrudesfromthetopandbottommounting
bracket(orflushwiththeendoftheslidebarfornewinstallations).
5. Removetheslidebarassemblycarefully,preventinganyfurthermovementbetween
theslidebarandtheslidebarsupports.
6.
Tightenthetwoslidebarclampingscrewsnomorethanhalfaturntosecuretheslide
barsupportstotheslidebar.
Caution!
Overtighteningthesescrewswillcausedamage.
7.
Fittheslidebarassemblyoverthemountingbrackets.Tightenthe2xM 4screwswith
the3 mmhexagonalkeysupplied.
Caution!
Do not
forceassemblyontothemountingbrackets,re-alignaslidebar
supportifrequired
.