Installing the Thermostatic Mixer

1.

  The thermostatic mixer must be fitted vertically 

as illustrated and can only be installed with 

rear supply inlets. the supply pipework 

must

 

be connected as follows:

hot to bottom Inlet

• 

cold to top Inlet

• 

bottom outlet.

• 

Important! 

this  product  does  not  allow  for 

reversed inlets.

2.

  determine the route for the hot and cold supply 

pipework.

Hot

Cold

Outlet

4.

  loosen  the  2  backplate  grubscrews  with 

the  2 mm  hexagon  key  (supplied)  and  pull 

the  mixer  and  concealing  plate  from  the 

backplate.

5. 

Unscrew the inlet nuts from the backplate.

concealing Plate

backplate

Inlet nuts

6.

  Using  the  backplate  as  a  guide,  mark  the 

positions  of  the  fixing  holes  and  the  pipe 

centres.

 

Note! 

make  sure  that  the  backplate  is  the 

correct way up (refer to illustration).

large boss 

must

 be 

fitted at the bottom

Summary of Contents for Infuse

Page 1: ...1 Installation User Guide These instructions must be left with the user Thermostatic Mixers Mira Infuse Mira Minibelle...

Page 2: ...afe level Inlet filters are fitted to protect the thermostatic cartridge Patents Patents GB 2 340 210 2 392 223 2 392 224 Patent Applications Euro 1 672 257 US 2006 0124758 A1 Contents Introduction 2...

Page 3: ...the infirm or anyone inexperienced in the correct operation of the controls 6 Rapid Excessive movement of the flow and or temperature control levers may result in momentary unstable blend temperatures...

Page 4: ...damage however this could detrimentally affect thermostatic performance For safety and performance reasons it is recommended that the maximum hot water temperature is limited to 65 C Cold Water Range...

Page 5: ...egulations and practices specified by the local water company or water undertakers Note Make sure that all site requirements correspond to the information given in section Specifications 1 The Mixer m...

Page 6: ...inlets 2 Determine the route for the hot and cold supply pipework Hot Cold Outlet 4 Loosen the 2 backplate grubscrews with the 2 mm hexagon key supplied and pull the mixer and concealing plate from th...

Page 7: ...mixer Failure to do so may result in product malfunction and will not be covered under the guarantee 11 Fit the olives onto the inlet pipework and tighten the inlet nuts using a suitable spanner Caut...

Page 8: ...tant A 12 litre minute flow regulator is fitted inside the outlet nipple This can be removed for gravity fed other low pressure systems 0 5 bar or below Hose Washer 12 L Min Flow Regulator 15 Turn on...

Page 9: ...it back one serration on the temperature control gear 6 Return the lever to the maximum temperature stop and check the temperature if it is still not hot enough repeat the procedure Lift the temperat...

Page 10: ...gulator fitted incorrectly Air lock or partial blockage in the pipework Symptom Water leaking from shower handset Cause Rectification Normal for a short period after shut off Check that the pressures...

Page 11: ...k Minibelle 1660 156 Temperature Knob Pack Infuse 1660 150 Backplate 1660 151 Concealing Plate 1660 154 Mixer Valve Assembly 1660 153 Inlet Nuts Olives x2 1660 152 Filter Pack x2 Not illustrated 1660...

Page 12: ...Services Team is comprehensively trained to provide every assistance you may need help and advice spare parts or a service visit Spare Parts We maintain an extensive stock of spares and aim to provid...

Reviews: