1062243-W2-N
Before fitting the cover, make sure that the appropriate cutouts have been removed
to suit the supply entering the product.
Thoroughly flush the mains-fed cold water supply pipe. The supply must be
clean and free from debris BEFORE connecting the appliance
.
To flush the pipework, turn on the water supply and drain a minimum of 10 litres
(2 gallons) of water into a bucket or catchment area. Turn off the water supply.
An installation template is supplied to help you install the Mira Azora.
Put the installation template on the wall and mark through the positions of the fixing
holes. Make sure that the position of these holes do not come in line with any buried
cables or pipework. Make sure that sufficient electrical supply cable is available for
connection to the terminal block.
Drill and plug the top two fixing holes. Secure the appliance to the wall with appropriate
screws. Drill the bottom fixing hole with the product in place. Alternative fixings (not
supplied) may be necessary for some wall structures. Avoid drilling into any supply
cable/pipe.
Install the mains-fed cold water supply
pipe. Do not overtighten.
(See Plumbing Installation Requirements).
Feed cable into Case. Fit Earth sleeve (not
supplied) and strip insulation.
Do not twist cable cores.
Important!
Make sure
that the inlet earth wire is
routed as shown. Failure
to do so may cause
product malfunction.