TIMEOUT PROGRAMMING: 

Phase

 

Description

 

Example

 

1

 

Shortly press the programming button of the MINI-RX. 
The LED on the receiver will blink every 2 seconds. 

 x 1 

 
 

 x 1  

 

2

 

Hold down the programming button of the MINI-RX for 
more than 3 seconds. The LED on the receiver will 
perform another blink.

 

 > 3s 

 
 

 x 1  

 

3

 

Press the programming button a number of times 
equal to the 

hours

 of activation you want to program: 

 

1 pressure -> 0 Hour 

2 pressures -> 1 Hours 

… 
10 pressures -> 9 Hours 
 
The receiver will blink 2 times at each button pressure.

 

 

n

 

 
 

 x 2  

 

4

 

Confirm the 

hours

 of operation by holding down the 

button programming of the MINI-RX for more than 3 
seconds. The receiver will perform a (long) blink.

 

 > 3s 

 
 

 x 1  

 

5

 

Press the programming button a number of times 
equal to the 

minutes

 of activation you want to 

program: 

 

1 pressure -> 0 minute 

2 pressures -> 1 minutes 

… 
60 pressures -> 59 minutes 
 
The receiver will blink 3 times at each button pressure.

 

 

n

 

 
 

 x 3  

 

6

 

Confirm the 

minutes

 of operation by holding down the 

button programming of the MINI-RX for more than 3 
seconds. The receiver will perform a (long) blink.

 

 > 3s 

 
 

 x 1  

 

Press the programming button a number of times 
equal to the 

seconds

 of activation you want to 

program: 
 
1 pressure -> 1 second 

2 pressures -> 2 seconds 

… 

59 pressures -> 59 seconds 
The receiver will blink 4 times at each button pressure.  

 

n

 

 
 

 x 4  

 

Summary of Contents for 33000148MIP

Page 1: ...coding functions remote control learning and anti noise digital filter The use of a SAW filter provides excellent selectivity and suppresses off band signals allowing the use of the product even in th...

Page 2: ...ECTRICAL CHARACTERISTICS Parameter Min Typ Max Unit Notes Supply voltage Vac 50 60Hz 207 253 Vac Power consumption Standby 1 5 W Operating frequency radio 433 92 MHz Free space range 150 meters Note 1...

Page 3: ...re and disposition of any obstacles interposed between transmitter and receiver Note 2 Time by power on to valid data reception Note 3 Time by command transmission pushing of remote or local key and e...

Page 4: ...pstream and downstream the product you need to disconnect power to the entire electrical system where the product is connected The installation of the device and the connected equipment should be perf...

Page 5: ...stallation not in accordance with applicable regulations and product specifications If the switching device is not close to the equipment you must have add another breaker device or a locking system t...

Page 6: ...ollowed by high signal for two base times 1 bit low signal for two base times duration followed by high signal for one base time Bit Amount from 12 to 40 Minimum number of decoded frames 2 One bit Zer...

Page 7: ...0 60Hz Operating frequency of radio receiver 433 92 MHz Modulation ASK OOK 1 relay output maximum current 16 Ampere Examples Pmax 230Vac 3680 VA per cos 1 Pmax 230Vac 3680 x cos VA per cos 1 Pmax 115V...

Page 8: ...he memory stored remote controls enables or disables the output of the receiver according to the functions described in paragraph 2 3 Functions Definitions The remote controls buttons are learned indi...

Page 9: ...d is not given via radio but from a hardwired input The entrance is located on the local terminal 1 and the change of state occurs when it is connected disconnected to from the line Standard recessed...

Page 10: ...reopen the switch the output is activated again Finally the bistable is the default mode in which receivers come out of the factory it is automatically reset after erasing the memory In case of voltag...

Page 11: ...ed remote controls 3 PROCEDURES MEMORY RESET Phase Description Example 1 Press and hold the programming button of the MINI RX until the LED on the receiver blinks twice shortly 3s x 2 2 After about 1...

Page 12: ...rols memory erasure does not reset the outputs settings x 5 5 End SINGLE REMOTE CONTROL ERASURE Phase Description Example 1 Press and hold the programming button of the MINI RX until the LED on the re...

Page 13: ...other blink 3s x 1 3 Press the programming button a number of times equal to the mode you want to program 1 pressure Monostable 2 pressures Bistable 3 pressures Timed 4 pressures Roll back to Monostab...

Page 14: ...essure x n x 2 4 Confirm the hours of operation by holding down the button programming of the MINI RX for more than 3 seconds The receiver will perform a long blink 3s x 1 5 Press the programming butt...

Page 15: ...e NOTE If you try to set a time of 0 seconds the MINI RX will set a default time of 60 seconds 8 Confirm the seconds of operation by holding down the button programming of the MINI RX for more than 3...

Page 16: ...pressures roll back to output 1 The system will notify the user the selection just made with a number of LED blinks fast equal to the selected output repeated every 2 seconds x n x n 4 Press the butto...

Page 17: ...5 34071 Cormons GO Italy declare that the product 33000148MIP 16A MINI RX complies with the essential requirements and other relevant provisions of Directives 2014 53 EU RED Directive Directive 2011...

Reviews: