12 GB
Dry your fitting with a cloth after every use to prevent any lime
deposits.
Clean the shower valve with a damp, soft cloth and, if necessary,
mild detergent.
Non-observance of the above care advice can be expected to result in
damage to the surfaces of the product. This will inevitably invalidate
the guarantee.
Replacing the cartridge
A cartridge
2
is a wear part that needs replacing according to the
hardness and / or degree of contamination of the water. This becomes
evident when the handle
5
becomes difficult to move.
A new cartridges
2
can be obtained from the listed service office.
Note:
This step requires an open-end spanner SW 27 mm or fitting pliers.
Proceed as follows to replace the cartridge
2
:
Shut off the main water supply. Allow any remaining water in the
pipework to drain.
Remove the hot / cold plaque
7
by adjusting the handle to the
highest position between the rim and the hot / cold plaque
7
and
the outside of the handle
5
.
Note:
Use light pressure to carefully push the hot / cold plaque
7
outward so as not to scratch the surface.
Loosen the locking screw
6
with the socket head wrench
8
by
turning it counter-clockwise.
CAUTION!
Do not completely unscrew the locking screw
6
.
Only loosen this as far as is necessary to remove the handle
5
.
Remove the handle
5
.