X705  Air Operated U.L.P.A. 15 AND 55 Gallon Vacuum

Do not at any time attempt to bypass, remove, substitute, or by any other means change the type of 
fi lters used in this vacuum. Use only approved Minuteman vacuum fi lters and fi lter bags.

Before attempting to use, and before cleaning, be certain that you fully understand the instructions given 
for the setting up and cleaning/changing of fi lters of this vacuum.

Since each facility has its own individual and unique cleaning problems, it is suggested that you use the 
following guidelines in determining the length of time between fi lter changes or cleaning the vacuum tank.

ASSEMBLY INSTRUCTIONS

1.  Take the paper fi lter protector #4 and insert into tank. Snap the elastic band around 

the rim of the tank. Allow two inches to overlap the tank rim.

2.  Place cloth fi lter bag assmebly #3 into tank. Center frame of fi lter around tank rim.
3.  Turn U.L.P.A. fi lter lid assembly #1 upside down on worktable. Center one pink 

impaction fi lter cartridge #2 onto U.L.P.A. fi lter.

4.  Place vacuum lid assembly #1 onto tank #5, center and fasten lid latches.

CLEANING AND EMPTYING INSTRUCTIONS

For the benefi t of your health, you should always wear a face mask and protective clothing approved and 
recommended by your Safety Department for the particular hazardous waste material you are working 
with. Check with your Safety Department or Industrial Hygienist for their instructions before attempting 
to clean out vacuum.

1.  Shut off  main air pressure valve feeding air to vacuum. Open air valve on vacuum 

lid to relieve pressure on line. If equipped with quick coupler, disconnect air pressure 
line.

2.  Carefully, and very slowly, remove vacuum lid only. (Be sure you have not accidentally 

lifted the cloth fi lter bag at the same time.) Set lid assembly aside

3.  Remove  cloth  fi lter  bag  with  bag  frame.  Check  for  residue  on  bag.  If  required, 

vacuum clean only. Do not shake bag in open atmosphere.

4.  Carefully undo the elastic band on the fi lter protector bag, fold in, and place this 

fi lter into proper disposal container.

5.  Reach into tank and gently push the collar of fi lter bag off  the tube, seal bag opening 

with  2”  wide  duct  tape,  and  carefully  remove  collector  bag  into  proper  disposal 
container.

Summary of Contents for X705

Page 1: ...Parts and Instruction Manual X705 Air Operated U L P A 15 55 Gallon Vacuums...

Page 2: ...l Dry Capacity 1 86 cu ft 7 16 cu ft Filtration 12 micron 99 999 efficiency 12 micron 99 999 efficiency Static Lift Max 180 180 Air Flow 166 CFM 166 CFM Air Line Diameter 1 2 ID 1 2 ID Max Airline Pre...

Page 3: ...SPECTION 4 SPECIAL WARNING 4 AIR PRESSURE AND C F M VOLUME REQUIRED 4 MAINTENANCE AND USAGE 4 OPERATION 4 ASSEMBLY INSTRUCTIONS 5 CLEANING AND EMPTYING INSTRUCTIONS 5 OVERVIEW 7 EXPLODED VIEWS 8 LID A...

Page 4: ...nts thinners fuels grain dust etc AIR PRESSURE AND C F M VOLUME REQUIRED For maximum performance operate with 1 2 air pressure line 80 PSI max 100 PSI and 37 input C F M Air pressure control valve can...

Page 5: ...er 4 Place vacuum lid assembly 1 onto tank 5 center and fasten lid latches CLEANING AND EMPTYING INSTRUCTIONS For the bene t of your health you should always wear a face mask and protective clothing a...

Page 6: ...enetration remove and place in disposal container 8 Visually check U L P A lter If lter shows signs of dust penetration revise cleaning and lter change procedure to be done more frequently Be absolute...

Page 7: ...Page 7 X705 Air Operated U L P A 15 AND 55 Gallon Vacuum OVERVIEW 3 3 3DSHU LOWHU 3 37 55 GALLON 3 3 3DSHU LOWHU 15 GALLON...

Page 8: ...Page 8 X705 Air Operated U L P A 15 AND 55 Gallon Vacuum LID ASSEMBLY EXPLODED VIEWS...

Page 9: ...ER 17 700017 1 PERFORATED SHEILD 18 700018 1 DOME FELT 19 700019 1 AIR DEFLECTOR 18GA 20 700021 1 POLYHOSE 32 LONG 21 700022PTD 1 COVER 701 PTD 22 700023PTD 1 OUTTER HOUSING PAINTED 23 700024 1 BOTTOM...

Page 10: ...Page 10 X705 Air Operated U L P A 15 AND 55 Gallon Vacuum 15 GALLON TANK ASSEMBLY...

Page 11: ...0 X 50 ZP 10 711352 2 NUT ACORN 1 4 20 NICKEL 13 711503 6 WASHER FLAT 10 X 50 ZP 14 711505 2 WASHER FLAT 1 4 ZP 15 711524 2 WASHER WAVE 52 X 87 X 01 16 711591 2 WASHER RUBBER 25 x 62 x 06 17 711594 2...

Page 12: ...Page 12 X705 Air Operated U L P A 15 AND 55 Gallon Vacuum 55 GALLON TANK ADAPTER ASSEMBLY...

Page 13: ...Y ALUMINUM 3 710530 1 SCR FHMS 8 32 X 50 BRASS 4 711372 1 NUT NYLOC 8 32 ZP 5 711502 1 WASHER FLAT 8 ZP 6 711503 6 WASHER FLAT 10 X 50 ZP 7 711542 1 WASHER LOCK 8 SPLIT ZP 8 711915 4 RIVET TUBE 3 16X...

Page 14: ...5 Air Operated U L P A 15 AND 55 Gallon Vacuum BILL OF MATERIAL ITEM PART NO QTY DESCRIPTION 1 900015PTD 1 TANK 55 GALLON W L DUMP VALVE 2 900047 1 DUMP VALVE 805046PKG DRUM LINER 55 GALLON PKG 12 55...

Page 15: ...16 NUT FLANGED WIZZ 5 16 18 ZP 2 711545 16 WASHER LOCK 5 16 SPLIT ZP 3 711642 2 PIN ROLL 3 16 X 1 00 4 750045 1 WELD DOLLY 30 55 5 761049 2 CASTR SWIVEL GRSE SEAL 6 761050 2 CASTER RIGID 5 7 900051 1...

Page 16: ...Page 16 X705 Air Operated U L P A 15 AND 55 Gallon Vacuum Notes...

Page 17: ...Page 17 X705 Air Operated U L P A 15 AND 55 Gallon Vacuum...

Page 18: ...ted items become the sole property of Minuteman or its original manufacturer whichever the case may be Minuteman disclaims any implied warranty including the warranty of merchantability and the warran...

Page 19: ...1yr 6months 12yrs 90 days A3S Blower 1yr 1yr 0 0 Phenom Dual Motor Upright Vacuums 2yrs 2yrs 0 0 Explosion Proof Vacuum 1yr 1yr 0 0 Propane Burnisher 1yr 1yr 0 90 days E14BQP and E14115 scrubber 1yr 1...

Page 20: ...hone 800 323 9420 www minutemanintl com A Member of the Hako Group Excellence Meets Clean Minuteman is a Full Line Manufacturer of Sweepers and Scrubbers for Industrial Facilities X705 Air Operated U...

Reviews: