5
OPERATING INSTRUCTIONS
1. Filling: Fill the solution tank with the desired amount of water and add liquid cleaning solution
to the proper dilution ratio. DO NOT USE powdered cleaning chemicals. Powders are unlikely
to dissolve thoroughly, resulting in clogging the in-line solution filter. This can reduce or stop
water flow to the brush.
2.
Close lid.
3. Lower brush assembly.
-
To lower the brush, first push the pedal slightly towards the center of the
machine (unlock it), then release it slowly.
-
To lift the brush, press the pedal down until lift mechanism engages.
4. Turn on brush switch.
5. Adjust solution control feed lever.
6. Turn on vacuum switch.
7. Lower Squeegee assembly.
After Use:
1. Turn off solution feed.
2. Switch off brush and raise.
3. Raise Squeegee assembly.
4. Turn off vacuum motor.
Solution and recovery tanks should be emptied after every use.
MAINTENANCE:
Daily
1. Clean float assembly & Squeegee blades. Vac filter.
2. Recharge batteries (check battery acid levels before and after
charging).
Monthly
1. Check wear on Squeegee blades.
2. Grease rear wheels.
3. Grease pivot points on brush motor assembly.
Every 500 hours check condition of carbon brushes on vacuum motor and brush
drive motor.
Summary of Contents for MC17000QP