Minuteman MBK-E SERIES User Manual Download Page 9

8

English

DO NOT

 plug Power Strips or Surge Protection Devices into

the ”Battery Backup” Receptacles on the UPS.  Plugging Power
Strips or Surge Protection Devices into the “Battery Backup”
Receptacles may cause internal damage to the UPS, the Power
Strip, or the Surge Protection Device.

WARNING!

CHARGING THE BATTERY

The MBK-E Series UPS will charge the internal batteries whenever the UPS is
connected to an AC source.  It is recommended that the UPS's batteries be
charged for a minimum of 4 hours before use.  The UPS may be used
immediately, however, the “ON Battery” runtime may be less than normally
expected.

CAUTION!

If the UPS indicates a Site Wiring Fault (SWF), have a
Qualified Electrician correct the problem.

Connecting to the Communications Port is optional.  The UPS works
properly without a connection.

NOTE:

CHECKING THE SITE WIRING FAULT

After plugging in the UPS, check the Site Wiring Fault (SWF) LED on the rear
panel of the UPS.  If the SWF LED is illuminated, the UPS is plugged into an
improperly wired AC outlet.

COMMUNICATIONS PORT CONNECTION

 (OPTIONAL)

MINUTEMAN Power Monitoring Software and interface cables kits can be used
with the MBK-E Series UPS.  Use only MINUTEMAN or MINUTEMAN ap-
proved interface cables with these UPSs.  Connect the USB interface cable  to
the USB communications port on the rear panel of the UPS.  Connect the other
end of the cable to the device that will be monitoring/controlling the UPS.

CONNECTING THE UPS TO AN AC SOURCE

Plug the UPS into a two pole, three wire, grounded receptacle only.  Do not use
extension cords, adapter plugs, power strips or surge strips.

NOTE:

If the UPS is going to be out of service or stored for a prolonged period
of time, the batteries must be recharged for at least twenty-four hours
every ninety days.

Connecting to the Network/Fax/Modem protection socket connection
is optional.  The UPS works properly without a connection.

NOTE:

NETWORK/FAX/MODEM PROTECTION CONNECTION

 (OPTIONAL)

Connect a 10 Base-T network, Fax or Modem line to the RJ11/RJ45 protection
sockets on the rear panel of the UPS.  This connection will require another
length of telephone or network cable.  The cable coming from the telephone
service or networked system is connected to the port marked “IN”.  The equip-
ment to be protected is connected to the port marked "OUT".

Summary of Contents for MBK-E SERIES

Page 1: ......

Page 2: ...duction 2 2 Controls and Indicators 5 3 Installation 7 4 Operation 9 5 Troubleshooting 11 6 Replacing the Battery 12 7 Obtaining Service 15 8 Specifications 16 9 Configurable Parameters Settings 17 10...

Page 3: ...d factory service if it is required If you experience a problem with the UPS please refer to the Troubleshooting guide in this manual to correct the problem or collect enough information so that the M...

Page 4: ...ipment may cause interference to radio and television reception If this equipment does cause interference to radio or television reception which can be determined by turning the equipment off and on t...

Page 5: ...systems peritoneal dialysis systems neonatal ventilator incubators ventilators for both adults and infants anesthesia ventilators and infusion pumps as well as any other devices desig nated as critica...

Page 6: ...C power to the load The LED blinks and the audible alarm sounds when supplying battery power to the load The LED blinks and no audible alarm when the UPS is in the boost mode The Fault red LED illumin...

Page 7: ...er receptacles are NEMA 5 15R type 5 The Dipswitches are for setting the Inverter output voltage and the transfer set points 6 The input power cord has a NEMA 5 15P Plug 7 The input circuit breaker wi...

Page 8: ...50 000 ft INSTALLATION Be sure to read the installation placement and all the cautions before installing the UPS Place the UPS in the final desired location and complete the rest of the installation p...

Page 9: ...N OPTIONAL MINUTEMAN Power Monitoring Software and interface cables kits can be used with the MBK E Series UPS Use only MINUTEMAN or MINUTEMAN ap proved interface cables with these UPSs Connect the US...

Page 10: ...is longer than the start up or user invoked test This test will run for approximately fifteen seconds to measure the battery s capability to provide an acceptable amount of runtime If the UPS fails a...

Page 11: ...tteries pass a self test If the battery is bad or disconnected the Weak Bad Battery LED will illuminate and the alarm will beep three times every five min utes until the battery is reconnected or repl...

Page 12: ...cations port Site Wiring Fault LED is illuminated Have a Qualified Electrician correct the service wiring The batteries may be weak or at the end of useful service life Charge the batteries for 8 hour...

Page 13: ...ies properly The batteries contain lead and pose a hazard to the environment and human health if not disposed of properly Refer to local codes for proper disposal requirements or return the battery to...

Page 14: ...n the front panel to turn the UPS OFF 3 Unplug the UPS s AC power cord from the AC wall outlet 4 Unplug the equipment from the output receptacles of the UPS 5 Unplug the computer interface cable from...

Page 15: ...6 Re install the battery bracket and the battery bracket retaining screw 17 Verify proper polarity Reconnect the battery negative black wire to the battery negative terminal 18 Verify proper polarity...

Page 16: ...s if possible F A technician will ask you for the above information and if possible help solve your problem over the phone In the event that the unit requires factory service the technician will issue...

Page 17: ...current capability one time 8 20 uS waveform 6500 Amps total Surge energy rating one time 10 1000 uS waveform Protection On battery waveshape Over current short circuit protected and latching shutdow...

Page 18: ...ry disabled 120 127VAC At first battery replacement reset to reflect actual number of days experience in your environment or leave factory default Enter the current date when replacing batteries Use t...

Page 19: ...arranty applies only to the original purchaser who must have properly registered the product within 10 days of purchase The warranty shall be void if a the equipment is damaged by the customer is impr...

Page 20: ...s or otherwise The sole and exclusive remedy for breach of any warranty expressed or implied concerning Para Systems s prod ucts and the only obligation of Para Systems hereunder shall be the repair o...

Page 21: ...urer s Address 1455 LeMay Drive Carrollton Texas 75007 USA Type of Equipment Uninterruptible Power Supplies UPS Model No MBK550E MBK750E I the undersigned hereby declare that the equipment specified a...

Page 22: ...21 Notes English...

Page 23: ...22 English Notes...

Page 24: ...23 Page do not print...

Reviews: